meddev-safety-classification
/meddev-safety-classification
Define how IEC 62304:2006+A1:2015 safety classification (Class A/B/C per 4.3) influences architecture, segregation, documentation, and testing—ensuring activity rigor scales with harm severity and software items are decomposed with defensible class assignments. Use when working on safety classification in medical device software.
- Author
- aminalam ↗
- Repository
- meddev-agent-skills ↗
- Licence
- MIT
- Last repository change
- 19.10.2026
Assessment and security
- Files in this package
- 1
- Scripts
- 0
- HTML comments
- 0
- URLs in SKILL.md
- 0
No signals detected. Repository changed on 19.10.2026, without references to retired models or APIs.
MIT, open: use and modify while retaining author attribution.
What it does and when to use it
Define how IEC 62304:2006+A1:2015 safety classification (Class A/B/C per 4.3) influences architecture, segregation, documentation, and testing—ensuring activity rigor scales with harm severity and software items are decomposed with defensible class assignments. Use when working on safety classification in medical device software.
Original author description
Define how IEC 62304:2006+A1:2015 safety classification (Class A/B/C per 4.3) influences architecture, segregation, documentation, and testing—ensuring activity rigor scales with harm severity and software items are decomposed with defensible class assignments. Use when working on safety classification in medical device software.
How it works
- Purpose
- When to Apply
- Requirements (testable)
- Recommended Practices
- Patterns
- Anti-Patterns (risks)
- Verification Checklist
- Traceability
- References
- Changelog
SKILL.md preview
---
name: meddev-safety-classification
description: Define how IEC 62304:2006+A1:2015 safety classification (Class A/B/C per 4.3) influences architecture, segregation, documentation, and testing—ensuring activity rigor scales with harm severity and software items are decomposed with defensible class assignments. Use when working on safety classification in medical device software.
license: MIT
metadata:
skill_id: ARCH-SAFETY-CLASS
version: 1.1.0
last_updated: '2026-05-21'
applies_to: Class A, Class B, Class C
jurisdiction: FDA, EU MDR, Global
prerequisites: REG-IEC62304, REG-ISO14971
category: architecture
---
# Software Safety Classification and Architectural Impact
## Purpose
Define how IEC 62304:2006+A1:2015 safety classification (Class A/B/C per 4.3) influences architecture, segregation, documentation, and testing—ensuring activity rigor scales with harm severity and software items are decomposed with defensible class assignments.
## When to Apply
- Early architecture and system hazard analysis.
- Decomposing a software system into items or units.
- Changes that alter hazard exposure, control placement, interfaces, or SOUP on safety paths.
- Problem investigations that suggest misclassification (see `DOC-PROBLEM-RES`).
## Requirements (testable)
1. Classification Flow [Class A, B, C]: Assign class from whether software can contribute to a hazardous situation and resulting harm severity after considering risk controls **outside** the software item only (hardware, independent software, procedures, etc.). Rationale: 4.3 a (interpretation).
2. Failure Assumption [Class A, B, C]: Treat software failure as possible when analysing contribution to hazardous situations; do not rely on probability of software failure to reduce class at assignment time. Rationale: 4.3 note (interpretation).
3. Class A [Class A]: Class A when software cannot contribute to a hazardous situation, or contribution does not yield unacceptable risk after external controls. Rationale: 4.3 a.
4. Class B [Class B]: Class B when contribution can yield unacceptable risk with serious injury not expected (non–serious injury harm). Rationale: 4.3 a.
5. Class C [Class C]: Class C when contribution can yield death or serious injury. Rationale: 4.3 a.
6. Re-classification [Class A, B, C]: Additional external controls may be added and class reassigned with documented rationale. Rationale: 4.3 a (second paragraph).
7. Risk File Record [Class A, B, C]: Document assigned class for each software system in the risk management file. Rationale: 4.3 c.
8. Decomposition [Class A, B, C]: Decomposed items inherit parent class unless documented rationale and segregation justify a different class. Rationale: 4.3 d–e.
9. Group Rule [Class A, B, C]: When applying processes to a group of items, use requirements of the highest class in the group unless lower class is justified in the risk file. Rationale: 4.3 f.
10. Default Class C [Class A, B, C]: Until class is assigned, apply Class C requirements. Rationale: 4.3 g.
11. Segregation [Class B, C]: Separate higher-class items from lower-class via process/memory/interface boundaries; Class C document segregation needed for risk control (5.3.5). Rationale: 4.3 d, 5.3.5.
12. Interface Contracts [Class B, C]: Validate interfaces between classes (bounds, timeouts, errors, integrity checks). Rationale: architectural risk control.
13. Evidence by Class [Class A, B, C]: Tailor architecture detail, design depth, and verification per Annex A class mapping (informative Table A.1); Class B/C architecture and integration; Class C detailed design and enhanced unit criteria. Rationale: 5.3–5.5.
14. Software Risk Controls [Class B, C]: Items implementing risk controls are classified based on the risk the control mitigates; develop per Clause 5. Rationale: 7.2.2. Skill: `REG-IEC62304-SWRM`.
15. Change Impact [Class A, B, C]: Reassess classification and segregation when functionality, interfaces, or hazards change. Rationale: 4.3, 6.2.2 (interpretation).
## Recommended Practices
- Maintain a per-item class table with justification, segregation method, and hazard links.
- Use MPU/MMU regions or process isolation for Class C vs non-safety code.
- Apply defensive serialization and checksum on inter-partition messages.
- Keep class-aware test depth (informative: MC/DC for Class C control logic where justified).
- Draw a decision diagram in the risk file (interpretation of 4.3 flow) without copying standard figures.
## Patterns
Class table (YAML):
```yaml
software_system: pump_firmware
system_class: Class C
rationale: HZ-07 serious injury if over-infusion; external clamp not sole mitigation
items:
- name: pump_control
class: Class C
inherits: pump_firmware
segregation: dedicated MPU region; no shared stack with ui_task
- name: ui_task
class: Class B
rationale: segregated; failure cannot corrupt pump_control memory (DES-SEG-02)
```
Interface validation snippet:
```c
// CLASS C boundary; REQ-IF-01; TEST-IC-12
int handle_cmd(const cmd_t *cmd, size_t len) {
if (len != sizeof(cmd_t)) return -1;
if (!crc_ok(cmd, len)) return -2;
return dispatch(cmd);
}
```
## Anti-Patterns (risks)
- Whole product labeled Class A without hazardous-situation analysis -> risk: under-verification.
- Using software reliability estimates to lower class at assignment -> risk: contradicts 4.3 failure assumption.
- Shared memory between Class C and utility code without protection -> risk: corruption.
- Decomposition to lower class without segregation evidence -> risk: audit challenge on 4.3 d.
- Risk-control software left at Class A -> risk: weak verification of mitigations (7.2.2).
## Verification Checklist
- [ ] System class documented in risk file with hazard linkage.
- [ ] Classification assumptions documented (external controls, failure treatment).
- [ ] Item-level classes documented; decomposition rationale where class differs.
- [ ] Group/process tailoring uses highest class unless risk-file exception.
- [ ] Until complete analysis, Class C controls applied.
- [ ] Segregation mechanisms implemented and reviewed for B/C (C: risk-control segregation).
- [ ] Interfaces across classes validated.
- [ ] Verification depth matches class; software risk controls classified per mitigated risk.
- [ ] Re-assessment performed after significant changes or problems.
## Traceability
- Link item class entries to hazards (`HZ-###`), controls (`RISK-CTRL-###`), and tests (`TEST-###`).
- Maintain class table under configuration control (`DOC-SCM`); reference in `DOC-DESIGN-DOCS`.
## References
- IEC 62304:2006+A1:2015, 4.3 (software safety classification).
- IEC 62304:2006+A1:2015, Annex A Table A.1 (informative class summary—clause IDs only).
- ISO 14971:2019 (`REG-ISO14971`).
- IEC TR 80002-1:2019 (informative).
- `REG-IEC62304-SWRM` (7.2.2 risk controls in software).
## Changelog
- 1.1.0 (2026-05-21): Aligned with 4.3 assignment rules, decomposition, default Class C, 7.2.2 control classification.
- 1.0.1 (2026-01-04): Audit correction - updated IEC TR 80002-1 to 2019 edition.
- 1.0.0 (2026-01-04): Initial skill covering class derivation, segregation, interfaces, and verification expectations.
## Audit History
- **2026-05-21**: IEC 62304 4.3 alignment pass.
- **2026-01-04**: Audit performed. IEC TR 80002-1:2009 updated to 2019 edition.
Versions
The database has no other skills named meddev-safety-classification.
Database snapshot: 13.11.2026 · package version 76542896c9a4 (SHA-256 digest of the entire package)
Downloads in the last 30 days: 0 · ranking
Report a problem with this skill: harmful content, incorrect descriptions or an author’s removal request.
Similar skills
- 100meddev-iec-62304
Provide actionable guidance to implement IEC 62304:2006+A1:2015 lifecycle processes—development, maintenance, software risk management, configuration management, and problem resolution—with rigor scaled by safety class (A/B/C). This hub skill indexes clause obligations; load… - 100meddev-software-requirements
Guide creation, verification, and maintenance of software system requirements derived from system needs (IEC 62304:2006+A1:2015, 5.2)—with content appropriate to the device, risk controls embedded for Class B/C, and evidence that requirements are testable and traceable. Use when… - 87medical-device-software-compliance
Reason about SaMD (Software as a Medical Device) regulatory compliance for FDA, EU MDR, and global submissions. Use when the user asks about IEC 62304 safety classification, ISO 14971 risk management, 21 CFR 820/QMSR quality system requirements, Design History File structure,… - 100neuro-soup-inventory
Build the IEC 62304 SOUP (software of unknown provenance) / third-party software inventory and SBOM starting point for neurotech device or analysis software from a code repository (requirements.txt, pyproject.toml, environment.yml, package.json, installed Python packages). Use…