Skip to content
Skills Library
Other · Tool integration

hardware-and-modules

/hardware-and-modules

Hardware and module management for SINAMICS drives. Use when plugging new hardware, changing module types, searching hardware catalog, projecting motor/encoder configurations, and managing master copies.

Licence
MIT
Last repository change
27.10.2026

Assessment and security

100/ 100Class: good
Format25 / 25
Frontmatter with name and description, valid name, description up to 1,024 characters, name matching the folder.
Discoverability25 / 25
Description explains when to use the skill, has a reasonable length and uses third person.
Content35 / 35
At least 150 words and at most 500 lines, headings, step lists, examples or code.
Hygiene15 / 15
No placeholders such as TODO, no Windows paths, with a licence.
Riskno signals detected in the scan
Files in this package
1
Scripts
0
HTML comments
0
URLs in SKILL.md
0
Deprecation

No signals detected. Repository changed on 27.10.2026, without references to retired models or APIs.

Licence

MIT, open: use and modify while retaining author attribution.

What it does and when to use it

Hardware and module management for SINAMICS drives. Use when plugging new hardware, changing module types, searching hardware catalog, projecting motor/encoder configurations, and managing master copies.

Original author description

Hardware and module management for SINAMICS drives. Use when plugging new hardware, changing module types, searching hardware catalog, projecting motor/encoder configurations, and managing master copies.

How it works

  1. Overview
  2. 🛑 MANDATORY CHECK BEFORE CODING: TypeIdentifier Requirement
  3. Required Namespaces
  4. Required Assemblies
  5. Common Patterns
  6. Quick Reference
  7. Related Files
  8. Exception Handling
Original SKILL.md headings · 385 lines, 2,389 words
SKILL.md preview
---
name: hardware-and-modules
description: Hardware and module management for SINAMICS drives. Use when plugging new hardware, changing module types, searching hardware catalog, projecting motor/encoder configurations, and managing master copies.
metadata:
  siemens-depends-on: "openness-base, devices-and-hardware"
---

# Hardware and Modules

## Overview

Hardware and module management in TIA Portal Openness covers inserting, replacing, deleting, and configuring SINAMICS hardware — motor modules, motors, encoders, and gearboxes. Use `PlugNew()` to insert hardware by `TypeIdentifier`, `ChangeType()` to replace module types, and the `HardwareCatalog` to search available products. Motor and encoder configuration is projected through `HardwareProjection`.

## 🛑 MANDATORY CHECK BEFORE CODING: TypeIdentifier Requirement

**BEFORE you write ANY code that creates hardware, you MUST ask the user for the `TypeIdentifier` of every hardware item they want to create.**

This is a **blocking requirement** — do NOT proceed to generate code without confirmed TypeIdentifiers.

### When to Ask

Ask the user for TypeIdentifiers when they request ANY of the following:
- Creating a device (S120, G115D, S7-1200, S7-1500, ET 200, etc.)
- Plugging a motor module (Single, Double)
- Plugging a motor (1FK7, etc.)
- Plugging an encoder
- Plugging an infeed (SLM, ALM, BLM)
- Plugging any hardware module (CBE20, VSM, terminal modules, etc.)

### How to Ask

Use the `ask_user` tool with a clear message. Example:

```
I need the TypeIdentifier for the hardware you want to create.

To find the TypeIdentifier in TIA Portal:
1. Go to Options → Settings → Hardware Configuration
2. Enable "Display of the Type Identifier"
3. Browse to the hardware module in the catalog
4. Copy the TypeIdentifier (e.g., OrderNumber:6SL3224-0BE32-0UA0/V2.9)

What TypeIdentifiers should I use for:
- [list each item needed]?
```

### What You Must NOT Do

- ❌ Do NOT assume or guess TypeIdentifiers
- ❌ Do NOT use example TypeIdentifiers from this documentation in production code
- ❌ Do NOT skip asking just because the user mentioned a product name (e.g., "S120", "1FK7") — the exact TypeIdentifier includes version info that is required
- ❌ Do NOT start generating code before you have all TypeIdentifiers

## Required Namespaces

```csharp
using System.Linq;
using Siemens.Engineering;
using Siemens.Engineering.HW;
using Siemens.Engineering.MC.Drives;
using Siemens.Engineering.MC.Drives.DFI;
```

## Required Assemblies

- `Siemens.Engineering.Base.dll`
- `Siemens.Engineering.Step7.dll`
- `Siemens.Engineering.Startdrive.dll`

## Common Patterns

### PlugNew — Insert Hardware Module by TypeIdentifier

**Description:** Plug a new hardware module (motor module, motor, etc.) into a device or drive axis using an order number / `TypeIdentifier`. Specify the item name and slot number.

**Example:**

```csharp
var motorModule = device.PlugNew("OrderNumber:6SL3120-1TE15-0Axx//10002", "MotorModule", 65535);
var motor = axisRack?.PlugNew("OrderNumber:1FK7011-xAK21-xTGx", "", 65535);
```

**Key Types and Methods:**
- `Device.PlugNew(typeIdentifier, name, slot)` — insert hardware at device level
- `DeviceItem.PlugNew(typeIdentifier, name, slot)` — insert hardware under a specific device item
- `TypeIdentifier` — string in format `"OrderNumber:<MLFB>"` or `"OrderNumber:<MLFB>//<version>"`

---

### ⚠️ PlugNew Hierarchy Rules for StartDrive (SINAMICS Devices)

When plugging hardware into StartDrive (SINAMICS) devices, the correct parent object matters. Follow these rules:

| Hardware Type | Plug Location | Slot/Position | Notes |
|---|---|---|---|
| **Devices** (SINAMICS drives) | `Project.Devices` | N/A | Always created directly in the project |
| **Single Motor Modules (Axis)** | Device | 65535 | Plugged directly to the S120 Device |
| **Double Motor Modules** | Device | 65535 | Plugged directly to the S120 Device |
| **Infeeds** (Active/Basic/Smart Line Module) | Device | 65535 | Plugged directly to the S120 Device |
| **Terminal Boards (TB30)** | Device | 65535 | Plugged directly to the S120 Device |
| **Terminal Modules (TM15, TM31, TM41, TM120, TM150)** | Device | 65535 | Plugged directly to the S120 Device |
| **DriveCliq Hubs** | Device | 65535 | Plugged directly to the S120 Device |
| **Voltage Sensing Modules (VSM)** | DeviceItem of Infeeds | 65535 | **Warning:** `PlugNew` returns a DeviceItem one layer below the created module. To plug further children, get `.Parent` first |
| **Motors** | The axis's own rack `DeviceItem` (`TypeIdentifier` starts with `System:Rack`) | 65535 | Plug onto the axis rack, not onto the nested motor-module item |
| **Encoders** | Auto-created when the motor is plugged (for DRIVE-CLiQ motor families that expose integrated encoder items) | N/A | No separate encoder `PlugNew` call is needed for those motor families |
| **Communication Board (CBE20)** | Control Unit (first DeviceItem under S120) | **3** | NOT slot 65535 — use position **3** |

**Critical Warnings:**

1. **`PlugNew` Return Value Shift:** When you plug an object onto a created module (e.g., VSM on Infeed), the returned `DeviceItem` is **one layer below** the expected device item. To plug further objects onto this module, access the **parent** of the returned value:

   ```csharp
   var vsmResult = infeedDeviceItem.PlugNew("OrderNumber:6SL3210-1NE30-0UA0/V2.9", "VSM", 65535);
   var actualModule = vsmResult.Parent; // Get the actual module to plug further children
   ```

2. **CBE20 Position Number:** The Communication Board CBE20 uses position **3**, NOT the default 65535. Use the wrong position and the plug will fail.

   ```csharp
   var controlUnit = s120Device.DeviceItems.First(); // First device item = control unit
   var cbe20 = controlUnit.PlugNew("OrderNumber:6SL3265-0AA00-0FA0/V2.9", "CBE20", 3);
   ```

3. **Double Motor Module auto-creates two axis racks — plug DRIVE-CLiQ motors onto the axis rack, not the module:** Plugging a Double Motor Module onto the S120 `Device` automatically creates two **sibling** axis-rack `DeviceItem`s, one per physical axis of the module. Resolve the rack structurally from the axis `DriveObject` / owning `DeviceItem`; do not identify it by an auto-generated display name. Plugging a motor onto the nested motor-module `DeviceItem` or `DRIVE-CLiQ interface` child fails or attaches it in the wrong place.

   ```csharp
   DeviceItem axisRack = axisDriveObject.Parent<DeviceItem>()
       ?? throw new InvalidOperationException("The axis DriveObject has no owning DeviceItem.");
   var motorItem = axisRack.PlugNew(motorTypeIdentifier, "", 65535);
   ```

   A successful motor plug can auto-create additional sibling encoder-related `DeviceItem`s on that rack (for example measuring-system / encoder-evaluation items). For those motor families, no separate encoder `PlugNew` call is needed or possible. This integrated-encoder rule does not apply to separately projected third-party or external encoders: configure those with `HardwareProjection.GetCurrentEncoderConfiguration` and `ProjectEncoderConfiguration`. Validate motor placement by recursively searching **that axis rack** for the motor `TypeIdentifier`, rather than searching the whole CU device where both axes may use the same motor type.

### Devices.CreateWithItem — Create Device from Catalog

**Description:** Create a new device instance directly from a hardware catalog `TypeIdentifier`.

**Example:**

```csharp
var device = Project.Devices.CreateWithItem(s210TypeIdentifier, "S210_New", "S210_NewDevice");
var g115d = Project.Devices.CreateWithItem("OrderNumber:6SL3500-xxxxx-xFxx/4.7.14", "", "");
```

**Key Types and Methods:**
- `Devices.CreateWithItem(typeIdentifier, name, deviceName)` — create device from catalog entry
- `Project.Devices` — collection of devices in the project

### ChangeType — Replace Hardware Module Type

**Description:** Change the `TypeIdentifier` of an existing motor module via `DriveItemHardwareModule.ChangeType()`. Useful for swapping hardware variants without removing and reinserting.

**Example:**

```csharp
var driveItemModule = driveAxisModule.GetService<DriveItemHardwareModule>();
driveItemModule.ChangeType(newTypeIdentifier);
```

**Key Types and Methods:**
- `DriveItemHardwareModule` — service exposing hardware module properties
- `ChangeType(typeIdentifier)` — replaces the module type in place

### Delete DeviceItem

**Description:** Remove a device item from the hierarchy.

**Example:**

```csharp
existingMotor.Delete();
```

**Key Types and Methods:**
- `DeviceItem.Delete()` — permanently removes the item from the device tree

### HardwareCatalog.Find — Search All Entries

**Description:** Query the hardware catalog for entries matching a search string. An empty string returns all entries.

**Example:**

```csharp
var hardwareCatalog = TiaPortalInstance.HardwareCatalog.Find(string.Empty);
var hardwareCatalog = TiaPortalInstance.HardwareCatalog.Find("S120");
```

**Key Types and Methods:**
- `TiaPortalInstance.HardwareCatalog` — global access to the hardware catalog
- `HardwareCatalog.Find(searchString)` — search method accepting partial matches

### ⚠️ `CatalogEntry` property names — do not guess by analogy

**Description:** `CatalogEntry` objects returned from `HardwareCatalog.Find(...)` do **not** use the property names that seem intuitive by analogy with other Siemens Openness types. The confirmed property names are:

| Expected-but-wrong name | Actual property |
|---|---|
| `Name` | `TypeName` |
| `OrderNumber` | `ArticleNumber` |
| — | `TypeIdentifier` (use this to `PlugNew`/`CreateWithItem`) |
| — | `Version` |

```csharp
var entries = TiaPortalInstance.HardwareCatalog.Find("1FK7");
foreach (var e in entries)
{
    Console.WriteLine($"{e.TypeName} | {e.ArticleNumber} | {e.TypeIdentifier} | {e.Version}");
}
```

If a property access throws `RuntimeBinderException`/`MissingMemberException` or returns unexpected data, verify the actual member names via reflection against the running instance rather than assuming the pattern from other services.

### Auto-slot convention: pass `65535` to let TIA Portal pick the first free slot

**Description:** Most `PlugNew(typeIdentifier, name, slot)` calls onto a SINAMICS device (motor modules, infeeds, terminal boards, terminal modules, DriveCliq hubs, motors, encoders) accept the sentinel slot value **`65535`**, which tells TIA Portal to auto-select the first free slot rather than requiring the caller to know or compute an exact slot number. This convention is not self-evident from the API surface and is easy to miss without prior TIA Portal GUI knowledge — see the hierarchy table below for the (rare) explicit-slot exceptions such as CBE20 (slot `3`).

### HardwareCatalog Find + Filter for DriveCliq Motors

**Description:** Find catalog entries matching a keyword, then filter by `CatalogPath` for sub-category refinement (e.g., DriveCliq motors).

**Example:**

```csharp
var motorEntries = hardwareCatalog.Find("motors")
    .Where(x => x.CatalogPath != null && x.CatalogPath.ToLower().Contains("cliq"))
    .ToList();
```

**Key Types and Methods:**
- `CatalogPath` — hierarchical path string for catalog categorization
- `TypeIdentifier` — unique product identifier from catalog entries

### Master Copy Create & Recreate Device

**Description:** Create a master copy of a device, delete the original, then recreate from the master copy. Useful for device cloning workflows.

**Example:**

```csharp
var masterCopy = masterCopiesFolder.MasterCopies.Create(device);
device.Delete();
var newDevice = Project.Devices.CreateFrom(masterCopy);
```

**Key Types and Methods:**
- `MasterCopyFolder` — container for master copies
- `MasterCopies.Create(device)` — create a master copy snapshot
- `Devices.CreateFrom(masterCopy)` — instantiate a new device from the copy

### Project Third-Party Motor Configuration

**Description:** Get current motor configuration, modify required and optional entries, then project the configuration back to the drive.

**Example:**

```csharp
var hardwareProjection = driveObject.GetService<DriveFunctionInterface>().HardwareProjection;
var motorConfiguration = hardwareProjection.GetCurrentMotorConfiguration(0);
motorConfiguration.RequiredConfigurationEntries.ToList()
    .ForEach(ce => { ce.Value = ...; });
motorConfiguration.OptionalConfigurationEntries.ToList()
    .ForEach(ce => { ce.Value = ...; });
motorConfiguration.SetEquivalentCircuitDiagramData(false);
hardwareProjection.ProjectMotorConfiguration(motorConfiguration, 0);
```

**Key Types and Methods:**
- `HardwareProjection` — manages hardware configuration projection
- `MotorConfiguration.RequiredConfigurationEntries` — mandatory configuration entries
- `MotorConfiguration.OptionalConfigurationEntries` — optional configuration entries
- `ProjectMotorConfiguration(config, slot)` — applies the configuration

### Project Third-Party Encoder Configuration

**Description:** Get current encoder configuration, modify entries by name, then project back.

**Example:**

```csharp
var hardwareProjection = driveObject.GetService<DriveFunctionInterface>().HardwareProjection;
var encoderConfig = hardwareProjection.GetCurrentEncoderConfiguration(0);
encoderConfig.RequiredConfigurationEntries.ToList()
    .ForEach(ce => { ce.Value = ...; });
hardwareProjection.ProjectEncoderConfiguration(encoderConfig, 1);
```

> **Verification required:** This `0`/`1` pairing is preserved from the empirical example, but the two APIs' indexing semantics still require live V21 verification before reuse. Verify the intended encoder/configuration slot for the specific device; `0`/`0` is not confirmed.

**Key Types and Methods:**
- `GetCurrentEncoderConfiguration(slot)` — retrieves current encoder settings
- `ProjectEncoderConfiguration(config, slot)` — applies encoder configuration

### ⚠️ External Encoder Code-Number Selection (G2xx OM ENC/OM DQ) — via `ChangeType()`, NOT `HardwareProjection`

**Description:** For G2xx drives (e.g. G210) with an external, terminal-wired
encoder module (`OM ENC`/`OM DQ`), the "Measuring system - Selection"
property (parameter `p400`, e.g. code `3001` = "1024 HTL A/B R") **cannot**
be set through any `DriveObject`/`HardwareProjection` API — every one of
these fails with the same error, regardless of which `DriveObject` is used
(including the encoder module's *own* `DriveObjectContainer`, which is a
separate, easy-to-miss `DriveObject` distinct from the axis/rack one):
- `DriveObject.Parameters.Find("p400")` and the index-based
  `Parameters.Find(400, 0)` both return `null` (not writable this way;
  `ReadParameters.Find("p400")` works fine for *reading* the current value).
- `HardwareProjection.GetCurrentEncoderConfiguration(0)` /
  `SetEncoder(...)` throw `EngineeringTargetInvocationException`: *"An error
  occurred while setting the attribute Result Predicate MDD Reading
  (MC_ComponentDataInfo) failed is not false."* — this happens on **every**
  `DriveObject` tried, which is the tell that `HardwareProjection` simply
  doesn't support this hardware family (it targets DRIVE-CLiQ/catalog
  motor-integrated encoders, not terminal/HTL-TTL external encoder modules).

The working fix instead uses `ChangeType()` — the same mechanism as
"ChangeType — Replace Hardware Module Type" above — but called on the
**encoder `DeviceItem` itself** (e.g. `"OM ENC_1"`), with a generic
"encoder data input" `TypeIdentifier`. This mirrors how a third-party/data-input
motor is selected via `"OrderNumber:XMxxxxx-xxxxx-xxxx//Motor data
input-Induction motors"` (`XM` prefix): the encoder equivalent uses an `XE`
prefix, with the version suffix encoding the interface family and code
number.

**Example:**

```csharp
// omEncDeviceItem = the OM ENC_1 / OM DQ_1 DeviceItem (NOT a DriveObject)
var driveItemModule = omEncDeviceItem.GetService<DriveItemHardwareModule>();
// e.g. "1024 HTL A/B R" == code number 3001
driveItemModule.ChangeType("OrderNumber:XExxxxx-xxxxx-xxxx//HTL_TTL.3001");
```

**How this was found:** `GetAttributeInfos()` and `DeviceItems` (children)
on the encoder `DeviceItem` show nothing encoder-related — no "Measuring
system" child object and no matching attribute. The `DriveItemHardwareModule`
service (with a settable `TypeIdentifier`) was only discovered via the
schema-free `GetServiceInfos()` enumeration (see [`engineering-objects`](../engineering-objects/SKILL.md) /
[`object-tree-walking`](../object-tree-walking/SKILL.md)), which lists it as a service the encoder
`DeviceItem` itself exposes — not something reachable through
`GetAttributeInfos()` or child `DeviceItems`.

**Key Types and Methods:**
- `DeviceItem.GetService<DriveItemHardwareModule>()` — get the module-type
  service directly from the encoder `DeviceItem` (not from a `DriveObject`)
- `DriveItemHardwareModule.ChangeType("OrderNumber:XExxxxx-xxxxx-xxxx//<InterfaceFamily>.<CodeNumber>")` — selects the encoder code number in place

### Set SimoGear MLFB via Commissioning

**Description:** Set the SimoGear material number on a G115D drive.

**Example:**

```csharp
var dfi = driveObject.GetService<DriveFunctionInterface>();
dfi.Commissioning.SetSimoGearMlfb("2KJ8001-2EA10-3FG1-D0X");
```

**Key Types and Methods:**
- `Commissioning.SetSimoGearMlfb(mlfb)` — sets the SimoGear material number

## Quick Reference

| Method/Pattern | Purpose |
|---|---|
| `PlugNew(typeId, name, slot)` | Insert a hardware module |
| `Devices.CreateWithItem(typeId, name, deviceName)` | Create device from catalog |
| `DriveItemHardwareModule.ChangeType(typeId)` | Replace module type in place |
| `DeviceItem.Delete()` | Remove device item |
| `HardwareCatalog.Find(searchString)` | Search hardware catalog |
| `MasterCopies.Create(device)` | Create master copy snapshot |
| `Devices.CreateFrom(masterCopy)` | Instantiate device from master copy |
| `GetCurrentMotorConfiguration(slot)` | Get motor configuration |
| `ProjectMotorConfiguration(config, slot)` | Apply motor configuration |
| `GetCurrentEncoderConfiguration(slot)` | Get encoder configuration |
| `ProjectEncoderConfiguration(config, slot)` | Apply encoder configuration |
| `omEncDeviceItem.GetService<DriveItemHardwareModule>().ChangeType("...//HTL_TTL.<code>")` | Select external encoder code number (G2xx OM ENC/OM DQ) — `HardwareProjection` does not support this hardware family |
| `Commissioning.SetSimoGearMlfb(mlfb)` | Set SimoGear material number |

## Related Files

- [`drive-objects`](../drive-objects/SKILL.md) — accessing `DriveObject` and `DriveFunctionInterface` required for commissioning
- [`networks-and-drivecliq`](../networks-and-drivecliq/SKILL.md) — network port wiring between hardware modules
- [`parameters`](../parameters/SKILL.md) — parameter-level hardware configuration
- [`telegrams`](../telegrams/SKILL.md) — data exchange configuration for plugged hardware

## Exception Handling

- `PlugNew()` throws if the `TypeIdentifier` is invalid or the slot is occupied. Validate the type identifier against the hardware catalog first.
- `ChangeType()` may fail if the new type is incompatible with existing connections. Disconnect ports before changing type.
- `Delete()` on a device item with active connections or references may throw `EngineeringException`. Clean up references before deletion.
- Hardware projection methods require the drive object to be properly configured. Call `GetCurrent*Configuration()` before modifying.
- If `HardwareProjection.GetCurrentEncoderConfiguration`/`SetEncoder` throws `"...Result Predicate MDD Reading (MC_ComponentDataInfo) failed is not false..."` regardless of which `DriveObject` is used, the drive's encoder is likely an external terminal-wired module (G2xx `OM ENC`/`OM DQ`) that `HardwareProjection` does not support — use `ChangeType()` on the encoder `DeviceItem`'s own `DriveItemHardwareModule` instead (see "External Encoder Code-Number Selection" above).

Versions

The database has no other skills named hardware-and-modules.

Database snapshot: 13.11.2026 · package version 7912834ca6d9 (SHA-256 digest of the entire package)

Downloads in the last 30 days: 1 · ranking

Report a problem with this skill: harmful content, incorrect descriptions or an author’s removal request.

Similar skills

  • 100parameters
    Drive parameters for SINAMICS drives. Use when reading/writing parameters, BiCo wiring, accessing parameters by index or name, and manipulating parameter bits.
  • 100safety-commissioning
    Safety commissioning for SINAMICS drives. Use when configuring PROFIsafe functions like STO and SImO, updating safety checksums, setting safety axis type, activating safety parameter bits, and managing acceptance tests.

Feedback and reports

Your message goes to Bartosz Sokoliński. An email address is needed only for a reply. See the privacy policy.