parameters

/parameters

Drive parameters for SINAMICS drives. Use when reading/writing parameters, BiCo wiring, accessing parameters by index or name, and manipulating parameter bits.

Licence
MIT
Last repository change
27.10.2026

Assessment and security

100/ 100Class: good
Format25 / 25
Frontmatter with name and description, valid name, description up to 1,024 characters, name matching the folder.
Discoverability25 / 25
Description explains when to use the skill, has a reasonable length and uses third person.
Content35 / 35
At least 150 words and at most 500 lines, headings, step lists, examples or code.
Hygiene15 / 15
No placeholders such as TODO, no Windows paths, with a licence.
Riskno signals detected in the scan
Files in this package
1
Scripts
0
HTML comments
0
URLs in SKILL.md
0
Deprecation

No signals detected. Repository changed on 27.10.2026, without references to retired models or APIs.

Licence

MIT, open: use and modify while retaining author attribution.

What it does and when to use it

Drive parameters for SINAMICS drives. Use when reading/writing parameters, BiCo wiring, accessing parameters by index or name, and manipulating parameter bits.

Original author description

Drive parameters for SINAMICS drives. Use when reading/writing parameters, BiCo wiring, accessing parameters by index or name, and manipulating parameter bits.

How it works

  1. Overview
  2. Required Namespaces
  3. Required Assemblies
  4. Common Patterns
  5. Quick Reference
  6. Related Files
  7. Exception Handling
Original SKILL.md headings · 136 lines, 666 words
SKILL.md preview
---
name: parameters
description: Drive parameters for SINAMICS drives. Use when reading/writing parameters, BiCo wiring, accessing parameters by index or name, and manipulating parameter bits.
metadata:
  siemens-depends-on: "openness-base, drive-objects"
---

# Parameters

## Overview

Drive parameters in SINAMICS drives are accessed through the `Parameters` collection on a `DriveObject`. Parameters can be retrieved by numeric index, by string name (e.g., `"r945[2]"`), or via `Find(index, subindex)` for BiCo wiring. Parameter bits provide granular control, enabling individual bit toggling for safety activation and feature flags.

## Required Namespaces

```csharp
using System.Linq;
using Siemens.Engineering;
using Siemens.Engineering.MC.Drives;
```

## Required Assemblies

- `Siemens.Engineering.Base.dll`
- `Siemens.Engineering.Step7.dll`
- `Siemens.Engineering.Startdrive.dll`

## Common Patterns

### BiCo Parameter Wiring

**Description:** Find a BiCo parameter by index and subindex, locate a target parameter bit, and assign the bit as the BiCo value. This creates a cross-wiring connection between parameters.

**Example:**

```csharp
var bicoParameter = redAxis.GetService<DriveObjectContainer>()
    .DriveObjects.First()
    .Parameters.Find(840, 0);

var connectedParameter = parameterBits.First(
    x => x.Name.Substring(x.Name.IndexOf('.') + 1) == "7");

bicoParameter.Value = connectedParameter;
```

**Key Types and Methods:**
- `Parameters.Find(index, subindex)` — locate a BiCo-capable parameter by numeric address
- `Parameter.Value` — assign a `ParameterBit` reference as the BiCo source
- `ParameterBits` — collection of available bit references for wiring

### Read Parameter Value

**Description:** Read the current value of a drive parameter by accessing its `.Value` property. This is the most common parameter operation — retrieving the current setting of a parameter like `r945` (motor rated current) or any other read/writable parameter.

**Example:**

```csharp
var parameter = driveObject.Parameters.Find("r945[2]");
if (parameter != null)
{
    var currentValue = parameter.Value;
    Console.WriteLine($"Parameter {parameter.Name} = {currentValue}");
}
```

**Key Types and Methods:**
- `Parameter.Value` — get the current value of the parameter
- `Parameter.Name` — the SINAMICS parameter name (e.g., `"r945[2]"`)

### Parameter Access by Index

**Description:** Access a drive parameter via numeric index from the `Parameters` collection. Direct index access is the fastest way to retrieve a known parameter.

**Example:**

```csharp
var parameters = driveObject.Parameters;
var parameterViaIndexAccess = parameters[100];
```

**Key Types and Methods:**
- `Parameters[index]` — indexer to retrieve a parameter by numeric ID
- `Parameter` — the returned parameter object with `.Value`, `.Name`, `.Bits`

### Parameter Access by String Name

**Description:** Find a parameter using `Parameters.Find(string)` with the parameter name, e.g., `"r945[2]"` for read-only parameters or `"p999"` for writable ones.

**Example:**

```csharp
var parameterViaStringAccess = parameters.Find("r945[2]");
```

**Key Types and Methods:**
- `Parameters.Find(name)` — locate parameter by SINAMICS naming convention
- Read parameters use `"r"` prefix; write parameters use `"p"` prefix

### Parameter Bit Access by Name

**Description:** Access a specific bit of a parameter via the `.Bits` collection and filter by the fully qualified bit name (e.g., `"p9603.1"`). Setting bit values enables individual features like safety functions.

**Example:**

```csharp
parameters.Find("p9603").Bits
    .Single(x => x.Name == "p9603.1")
    .Value = 1;
```

**Key Types and Methods:**
- `Parameter.Bits` — collection of individual bits within a parameter
- `Bit.Name` — fully qualified name in `"parameter.bit"` format
- `Bit.Value` — set or read the bit value (0 or 1)

## Quick Reference

| Method/Pattern | Purpose |
|---|---|
| `Parameter.Value` (read) | Read the current value of a parameter |
| `Parameters.Find(index, subindex)` | Locate BiCo parameter by numeric address |
| `Parameters[index]` | Direct index access to a parameter |
| `Parameters.Find("r945[2]")` | Find parameter by string name |
| `Parameter.Bits.Single(x => x.Name == "p9603.1").Value` | Access and set individual parameter bits |
| `Parameter.Value = bit` | Assign a BiCo wiring connection |

## Related Files

- [`drive-objects`](../drive-objects/SKILL.md) — obtaining the `DriveObject` whose `Parameters` collection you access
- [`safety-commissioning`](../safety-commissioning/SKILL.md) — uses parameter bit writes (e.g., `p9603`, `p9604`) to activate safety functions
- [`telegrams`](../telegrams/SKILL.md) — telegram configuration interacts with parameter-based addressing
- [`hardware-and-modules`](../hardware-and-modules/SKILL.md) — hardware projection sets configuration entries that map to parameters

## Exception Handling

- `Parameters.Find(string)` returns `null` if the parameter name does not exist. Always check for null before accessing properties.
- `Parameters[index]` throws `IndexOutOfRangeException` for invalid parameter numbers.
- `Parameter.Bits.Single()` throws `InvalidOperationException` if the bit name is not found. Use `FirstOrDefault()` with null checks for robust code.
- Writing to read-only parameters (e.g., `"r..."` prefix) throws `EngineeringException`. Only `"p..."` parameters are writable.
- BiCo wiring requires both source and target to support BiCo. Verify BiCo capability before assignment.

Versions

RepositoryScoreLicence
This page · asckye/tia_portal_openness_mcp100MIT
thedaviddias/front-end-checklist100MIT
Alejo2075/claude-code-aws90MIT

Database snapshot: 13.11.2026 · package version a74778c091d8 (SHA-256 digest of the entire package)

Downloads in the last 30 days: 0 · ranking

Report a problem with this skill: harmful content, incorrect descriptions or an author’s removal request.

Similar skills

  • 100drive-objects
    Drive objects and DriveFunctionInterface for SINAMICS drives. Use when locating DriveObjects, setting telegrams, writing drive parameters (scalar, BiCo, bit, indexed, DFI motor/encoder), handling Double-MoMo drives, refreshing drive state after writes, or accessing/deactivating drive objects.
  • 100safety-commissioning
    Safety commissioning for SINAMICS drives. Use when configuring PROFIsafe functions like STO and SImO, updating safety checksums, setting safety axis type, activating safety parameter bits, and managing acceptance tests.

Feedback and reports