unit-ops-liquid-liquid-extraction
/unit-ops-liquid-liquid-extraction
Opisuje ekstrakcję ciecz-ciecz: odzysk rozpuszczalnika, fazę rozproszoną, wybór kontaktora i pozycję granicy faz.
- Autor
- ChemE-as-Code ↗
- Repozytorium
- core ↗
- Licencja
- AGPL-3.0
- Ostatnia zmiana repozytorium
- 13.11.2026
Ocena i bezpieczeństwo
- Pliki w paczce
- 1
- Skrypty
- 0
- Komentarze HTML
- 0
- Adresy URL w SKILL.md
- 0
Brak sygnałów. Repozytorium zmienione 13.11.2026, bez odwołań do wycofanych modeli i API.
AGPL-3.0, copyleft: przeróbki udostępniane innym muszą mieć tę samą licencję.
Co robi i kiedy
Opisuje ekstrakcję ciecz-ciecz: odzysk rozpuszczalnika, fazę rozproszoną, wybór kontaktora i pozycję granicy faz.
Oryginalny opis (EN)
Liquid-liquid extraction - why solvent recovery belongs on the flowsheet from the start, the two-product recovery loop, contactor choice, which phase is dispersed and what interface position implies. Use when an extractor, mixer-settler or solvent recovery is designed or reviewed.
Jak działa
- Purpose and when to use
- Required inputs and missing inputs
- Workflow and tools
- Validation and failure handling
- Outputs and provenance
- Required human judgment
- References
Podgląd SKILL.md
--- name: unit-ops-liquid-liquid-extraction description: Liquid-liquid extraction - why solvent recovery belongs on the flowsheet from the start, the two-product recovery loop, contactor choice, which phase is dispersed and what interface position implies. Use when an extractor, mixer-settler or solvent recovery is designed or reviewed. --- # Liquid-liquid extraction ## Purpose and when to use Extraction is chosen when distillation cannot do the job economically: close relative volatility, an azeotrope that will not break, a heat-sensitive product, a non-volatile metal ion, or a dilute organic in an aqueous effluent (Ray and Das, *Process Equipment and Plant Design*, Elsevier 2020, Ch 13). Solvent recovery usually costs more than the extraction in capital and operation, so it belongs on the flowsheet from the first sketch. ## Required inputs and missing inputs Feed and solute, candidate solvent and its mutual solubility, liquid-liquid equilibrium data, density difference, interfacial tension, number of stages needed. Core has no liquid-liquid equilibrium for this; ask for data or state the gap. ## Workflow and tools Engineering guidance only; core has no calculation for this. Extraction can be represented as a `component_separator` with specified recoveries (`separation-method-selection`, untested, no LLE); `phase-calculation` can check whether a mixture splits into two liquid phases. Loop: feed and solvent enter; two streams leave, extract and raffinate, both needing solvent recovery (normally distillation); recovered solvent plus make-up returns. The minimum flowsheet is one extractor and two recovery columns. Contactor (indicative bands that overlap; a cost and plot decision where two serve): | Service | Contactor | |---|---| | Easy phase separation, up to about 3 stages | Static column (spray, packed, sieve tray) | | Easy separation, about 3 to 8 stages | Mixer-settler battery | | Moderate difficulty, up to about 8 stages | Agitated column (reciprocating plate, rotating disc, pulsed) | | Difficult phase separation, few stages | Centrifugal contactor | Commercial equipment gives roughly one to eight theoretical countercurrent stages. Efficiency is 80 % and up for mixer-settlers, possibly under 30 % on sieve trays; disappointing efficiency is usually incomplete settling, not poor mixing. Bubble caps are not used. Dispersed phase: in sieve tray and packed towers the higher-flow phase is dispersed, in other column types the lower-flow phase. An interface at the top means the light phase is dispersed; at the bottom, the heavy phase, and the interface needs a level controller. The phase wetting the internals should be continuous. Choice also follows density, viscosity, flow ratio, flooding and materials; dispersing a flammable liquid reduces its holdup but raises interfacial area and carryover, so it is a documented project decision. Where densities are close, centrifugal force does the separating. Practical points: a smaller immiscibility envelope needs more solvent, and it shrinks with temperature; too-low interfacial tension gives a stable dispersion, worsened by dust and surfactants; some towers hold the ends at different temperatures with a pump-back. ## Validation and failure handling Questions for a design: recovery on only one product; no make-up solvent; no interface level control; no coalescer or settler where phases separate slowly; no path for solvent degradation products. ## Outputs and provenance State the contactor, dispersed phase and recovery arrangement with sources. Record in `DESIGN.md`. ## Required human judgment Solvent selection, dispersed phase, and handling of flammable or toxic solvents need a person. ## References - Ray and Das, *Process Equipment and Plant Design*, Elsevier 2020, Ch 13. - `separation-method-selection`, `phase-calculation`, `unit-ops-distillation`. - Retained as general method: loop structure, interface logic. - Needs review before operational use: contactor stage bands and efficiencies.
Wersje
W bazie nie ma innych skilli o nazwie unit-ops-liquid-liquid-extraction.
Migawka bazy z 13.11.2026 · wersja paczki d49ed0f9774e (skrót SHA-256 całej paczki)
Pobrania w ostatnich 30 dniach: 0 · ranking
Zgłoś problem z tym skillem: szkodliwa treść, błędny opis albo prośba autora o usunięcie.
Podobne skille
- 90unit-ops-absorption-and-stripping
Opisuje absorbery i strippery jako jeden system z obiegiem rozpuszczalnika, regeneracją, uzupełnianiem strat i sterowaniem. - 90unit-ops-phase-separation
Opisuje separatory gaz-ciecz, odsadzacze, płuczki i koalescery, ich mechanizmy działania, orientację i sterowanie. - 100neqsim-produced-water-and-solids-separation
Prowadzi agentów przez oczyszczanie wody produkowanej i separację ciał stałych w NeqSim: usuwanie oleju, hydrocyklony, flotację, odwadnianie, filtrację, krystalizację i ekstrakcję ciecz-ciecz.