first-contact
/first-contact
Diagnozuje połączenie sprzętowe, które nie odpowiada: brak mostka, linia bez echa albo bezsensowne odczyty ze sterownika silnika.
- Autor
- MZULALI ↗
- Repozytorium
- xj-scanner ↗
- Licencja
- GPL-3.0
- Ostatnia zmiana repozytorium
- 10.11.2026
Ocena i bezpieczeństwo
- Pliki w paczce
- 1
- Skrypty
- 0
- Komentarze HTML
- 0
- Adresy URL w SKILL.md
- 0
Brak sygnałów. Repozytorium zmienione 10.11.2026, bez odwołań do wycofanych modeli i API.
GPL-3.0, otwarta.
Co robi i kiedy
Diagnozuje połączenie sprzętowe, które nie odpowiada: brak mostka, linia bez echa albo bezsensowne odczyty ze sterownika silnika.
Oryginalny opis (EN)
Debug a hookup that is wired but not talking to the engine computer - no bridge, line idles HIGH, no echo, or nonsense values. Use when the first reading fails or a working setup stops answering.
Jak działa
- 1. Laptop ↔ Nano
- 2. The idle level
- 3. Echo
- 4. Look at the wire itself
- 5. It worked and then stopped
Podgląd SKILL.md
--- name: first-contact description: Debug a hookup that is wired but not talking to the engine computer - no bridge, line idles HIGH, no echo, or nonsense values. Use when the first reading fails or a working setup stops answering. --- # It's wired but nothing answers Find which layer is broken before changing anything. Go in this order and stop at the first one that fails. ## 1. Laptop ↔ Nano `.venv/bin/python pc/xj_scan.py --cli auto --codes` and read the first lines. - `No Arduino found on USB`: cable or port. `ls /dev/cu.*` before and after plugging in. - `No bridge answered`: the sketch isn't on the Nano, or something else holds the port. Re-upload `arduino/xj_bridge`. - `Bridge found: XJBRIDGE 1.0`: this layer is fine. ## 2. The idle level The scanner prints `PCM transmit line idle check: IDLE HIGH% n`. - **Near 0, "idles LOW"**: the computer is powered and wire A is connected. Go to 3. - **Near 100, "idles HIGH"**: one of: key is off; wire A isn't touching in its cavity; wires A and B are swapped. Have them check the key, reseat wire A, and re-measure cavities 3 and 4 with the meter (5 V is B, 0 V is A). - **Never LOW and there is a resistor from D10 to 5 V**: remove it. That pull-up is what blocked the first attempt on the test car; see [docs/wiring.md](../../../docs/wiring.md). - **In between, "busy or noisy"**: ground. Check wire C end to end. ## 3. Echo - `No echo for byte 14`: the computer isn't hearing the Nano. Wire B (D11 to the 5 V cavity) or ground. Check continuity from the spade to the Nano pin. - `Echo mismatch`: try `--byte-order swap`. - Echo works but values are wild (battery 3 V or 40 V): byte order again, `--byte-order swap` or `normal`. ## 4. Look at the wire itself When the steps above don't explain it, upload `arduino/xj_sniff` and run `.venv/bin/python tools/sniff.py`. It sends `14`, `0A` and `10` in both polarities and prints what came back on D10. - An echo of the sent byte in inverted polarity: wiring is right. - Edges but garbage: wrong polarity or a bad ground. - No edges at all: wire A or B isn't connected to the computer. Upload `arduino/xj_bridge` again afterwards. ## 5. It worked and then stopped Almost always a spade terminal that backed out, or the key got turned off. Reseat, key ON, run `--codes` again. Full symptom table: [docs/troubleshooting.md](../../../docs/troubleshooting.md).
Wersje
W bazie nie ma innych skilli o nazwie first-contact.
Migawka bazy z 13.11.2026 · wersja paczki 1150c5c10341 (skrót SHA-256 całej paczki)
Pobrania w ostatnich 30 dniach: 0 · ranking
Zgłoś problem z tym skillem: szkodliwa treść, błędny opis albo prośba autora o usunięcie.
Podobne skille
- 100hookup
Prowadzi przez podłączenie Arduino Nano do diagnostycznego gniazda jeepa z lat 1991 do 1995 i pierwszy odczyt z komputera silnika.