building-simulink-models
/building-simulink-models
Buduje i edytuje modele Simulink, System Composer, Stateflow i Simscape: strukturę modelu, parametry, porty, połączenia oraz wnętrze wykresów Stateflow.
- Autor
- matlab ↗
- Repozytorium
- simulink-agentic-toolkit ↗
- Licencja
- BSD-2-Clause
- Ostatnia zmiana repozytorium
- 21.10.2026
Ocena i bezpieczeństwo
- Pliki w paczce
- 5
- Skrypty
- 0
- Komentarze HTML
- 0
- Adresy URL w SKILL.md
- 1
Brak sygnałów. Repozytorium zmienione 21.10.2026, bez odwołań do wycofanych modeli i API.
BSD-2-Clause, otwarta.
Co robi i kiedy
Buduje i edytuje modele Simulink, System Composer, Stateflow i Simscape: strukturę modelu, parametry, porty, połączenia oraz wnętrze wykresów Stateflow.
Oryginalny opis (EN)
Builds and edits Simulink, System Composer, Stateflow, and Simscape models. Use when modifying model structure, parameters, ports, connections, or Stateflow chart internals.
Jak działa
- When to Use
- When NOT to Use
- Library & Policy Prerequisites — BLOCKING GATE
- Workflow
- Operation Chaining with ref
- Guardrails
- Naming Conventions
- Block Types
- Review Gate
- Domain-Specific Rules
Podgląd SKILL.md
---
name: building-simulink-models
description: Builds and edits Simulink, System Composer, Stateflow, and Simscape models. Use when modifying model structure, parameters, ports, connections, or Stateflow chart internals.
license: https://www.mathworks.com/content/dam/mathworks/license/pmrl/license.md
metadata:
author: MathWorks
version: "1.5"
---
# Building Models
Use `model_edit` for all structural changes — Simulink, System Composer, Simscape, and Stateflow chart internals
## When to Use
- Adding, connecting, deleting, or replacing blocks in a model
- Configuring block parameters, signal properties, or model settings
- Creating or editing Stateflow chart internals (states, transitions, junctions, data, events, messages, functions)
- Building System Composer architecture models
- Wiring Simscape physical connections
## When NOT to Use
- Querying parameter values → use `model_query_params`
- Resolving variable references to numeric values → use `model_resolve_params`
## Library & Policy Prerequisites — BLOCKING GATE
**Do this FIRST — evaluate the result before any other tool call.** Do not narrate the gate check to the user; proceed silently based on the result.
Call `library.settingsLookup()` to check for custom library configuration. It returns a struct with resolved absolute paths:
- `found` — whether a libraries file was located (satk-libraries.json or legacy reuse-libraries.json)
- `enabled` — whether custom libraries are configured
- `gatePass` — whether the gate is satisfied (can proceed to build)
- `kgIndexPath` — absolute path to `library-kg/index.md`
- `librariesPath` — absolute path to the libraries file
- `policyPath` — absolute path to `block-policy.json`
- `dataRoot` — absolute path to the directory containing `.satk/`
**Interpret the result:**
- **`found: false`** → no custom libraries configured. Proceed with standard Simulink blocks.
- **`gatePass: true, found: true`** → read `kgIndexPath` for block lookup, then plan and edit.
- **`gatePass: false`** → invoke `setup-custom-libraries` to populate the Knowledge Index.
Display meaningful description of each check and result instead of stating gate Pass/fail.
No model reading, planning, or editing begins until the gate passes.
## Workflow
0. **Ensure Library & Policy Prerequisites:** See BLOCKING GATE above. Do not proceed until gates pass.
1. **Library block lookup:** List every block type you plan to use, search `.satk/library-kg/index.md` and the relevant category pages to find each of the library blocks that match.
2. **Read first:** Use `model_read` on the target scope to get block IDs and understand existing topology.
3. **Plan the data flow:** For complex edits, sketch inputs → operations → outputs, then map to blocks identified in Step 1 & 2.
4. **Edit:** Use `model_edit` with operations scoped to one subsystem level at a time.
5. **Verify:** Use `model_read` on the scope to confirm the structure matches your intent.
6. **Check connectivity:** After all edits in a scope are complete, run `model_check` to catch unconnected ports or dangling lines. Fix any `error`-severity issues.
**If `model_edit` returns `status: partial`:** Run both `model_read` and `model_check` immediately — don't wait until all edits are complete.
## Operation Chaining with `ref`
Use `ref` to name a block and `#ref` to reference it in later operations within the same call:
```json
[{"op": "add_block", "type": "Gain", "name": "MyGain", "ref": "g1"},
{"op": "connect", "target": "blk_5.y1 -> #g1.u1"}]
```
In SF scope, `#ref` references are portless — no `.y1`/`.u1` suffixes (see `references/stateflow.md`).
The response `created` map shows `ref → blk_id` (or `ref → sf_X` in SF scope). In subsequent calls, use the returned ID — `#ref` only works within a single call.
## Guardrails
- **Never manually construct block path strings** from names shown in `model_overview` or `model_read`. Block names can contain invisible newlines and trailing whitespace that cause `hilite_system`, `open_system`, and `get_param` to fail. Instead, resolve paths from `blk_X` IDs:
```matlab
% blk_42 → use the number after "blk_" as the SID
blockPath = Simulink.ID.getFullName('<ModelName>:42');
hilite_system(blockPath)
open_system(blockPath)
get_param(blockPath, 'BlockType')
```
- Do not call `Simulink.BlockDiagram.arrangeSystem` or use `set_param` for block positioning unless the user explicitly requests it. `model_edit` has a built-in autolayout engine that runs automatically after each call.
- Always pass `layout_mode` to `model_edit`. Use `"full"` when populating an empty scope (new model root, or a newly-created subsystem) for optimal block arrangement. Use `"incremental"` when adding blocks to a scope that already has existing blocks (preserves existing positions).
- Each `model_edit` call operates in exactly one domain (Simulink, System Composer, or Stateflow) determined by the scope. To add a Chart block and then populate it, use two calls: SL scope for the Chart block, then SF scope for internals. Use `model_read` between calls to discover the chart's `sf_X` scope ID.
- Use meaningfully named variables (e.g., `Kp_SpeedController`) instead of hardcoded numeric values. Define variables in model workspace or a `.m` init script.
- Don't use `evaluate_matlab_code` with `set_param`/`add_block` to bypass `model_edit` — it skips autolayout, undo tracking, and error recovery
- Use `open_system` rather than `load_system` to open models that are not already open, or when creating new models, unless the user explicitly asks otherwise or the model is a library. This ensures the user can see live edits as they happen.
## Naming Conventions
Prefer code-generation-safe names for blocks, signals, and variables:
- Use only: `a-z`, `A-Z`, `0-9`, underscore (`_`)
- Don't start with a number
- Don't use leading/trailing or consecutive underscores
- Prefer names under 32 characters (required for some code generation targets)
## Block Types
Use the block's **display name** in the `type` field. Do not construct or guess library paths.
- **Custom library blocks (from `satk-libraries.json`):** pass both `type` AND `ReferenceBlock` fields. Set `type` to the block's display name and `ReferenceBlock` to the full library path from the library KG.
- **Toolbox KB blocks (from `activeToolboxes`):** Use them exactly like custom library blocks — reference the `type` and `ReferenceBlock` fields from the toolbox category page in the library KG.
- **Built-in Simulink blocks:** Use the BlockType directly: `Gain`, `Sum`, `Constant`, `Integrator`, `SubSystem`, `Scope`
- **Library blocks (Simscape, Aerospace, DSP, Communications, etc.):** Use the display name as it appears in the Simulink Library Browser: `Voltage Source`, `Resistor`, `DC Motor`, `Solver Configuration`, `6DOF (Euler Angles)`
- **If `model_edit` returns `INVALID_TYPE`:** Fall back to the full library path from MATLAB documentation (e.g., `ee_lib/Sources/Voltage Source`)
```json
[{"op": "add_block", "type": "In", "ReferenceBlock": "customLib_Portsandsubsystems/In", "name": "Voltage", "ref": "v1"},
{"op": "add_block", "type": "Gain", "ReferenceBlock": "customLib_Mathoperations/Gain", "name": "Kp", "ref": "g1"},
{"op": "add_block", "type": "Add", "ReferenceBlock": "customLib_Mathoperations/Add", "name": "SumErr", "ref": "s1"},
{"op": "add_block", "type": "Out", "ReferenceBlock": "customLib_Portsandsubsystems/Out", "name": "Output", "ref": "o1"}]
```
```json
[{"op": "add_block", "type": "Voltage Source", "name": "V1", "ref": "v1"},
{"op": "add_block", "type": "Resistor", "name": "R1", "ref": "r1"},
{"op": "add_block", "type": "Electrical Reference", "name": "Gnd", "ref": "gnd"},
{"op": "add_block", "type": "Solver Configuration", "name": "Solver", "ref": "sc"}]
```
## Review Gate
After completing all edits for a scope, verify:
- No `error`-severity issues from `model_check` (unconnected ports, dangling lines)
- All `ref` names resolved to `blk_id` in the `created` map — no dangling `#ref` references in subsequent calls
- Stateflow charts pass lint (`model_check` with `checks='["stateflow_lint"]'`) before layout is applied
- If `model_edit` returned `status: partial` at any point, confirm the scope is now structurally complete via `model_read`
## Domain-Specific Rules
When working with these domains, read the corresponding reference file before editing:
- **Stateflow charts** -> `references/stateflow.md` — `model_edit` edits chart internals natively. Scope to a chart (`sf_X` or chart `blk_X`) and use the same operations: `add_block` for SF elements, portless `connect` for transitions, `configure` for properties. The reference covers SF-specific syntax, scoping, LabelString patterns, and the two-call SL+SF workflow.
- **System Composer architecture models** -> `references/system-composer.md` — Create models with `systemcomposer.createModel`, then use `model_edit`. Components use `type: "SubSystem"`, ports use Bus Element blocks. The reference covers component creation, port wiring, and behavior model generation.
- **Simscape physical models** -> `references/simscape.md` — Physical connections use bidirectional `<->` syntax. The reference covers connection semantics, port patterns, and initial target variables.
----
Copyright 2026 The MathWorks, Inc.
----
Pliki w paczce (5)
- SKILL.md 9 KB
- manifest.yaml 1 KB
- references/simscape.md 3 KB
- references/stateflow.md 9 KB
- references/system-composer.md 4 KB
Wersje
| Repozytorium | Wynik | Licencja |
|---|---|---|
| Ta strona · matlab/simulink-agentic-toolkit | 100 | BSD-2-Clause |
| zrwangems/dsh-zrwang-plugin | 100 | MIT |
| 3154410240smh-arch/aircraft-control-modeling | 100 | Apache-2.0 |
Migawka bazy z 13.11.2026 · wersja paczki b68270b99600 (skrót SHA-256 całej paczki)
Pobrania w ostatnich 30 dniach: 1 · ranking
Zgłoś problem z tym skillem: szkodliwa treść, błędny opis albo prośba autora o usunięcie.
Podobne skille
- 95simulink-automation
Analizuje i modyfikuje modele Simulink przez MATLAB Engine: topologię, parametry i cykl życia modelu. - 100simulink-model-check
Sprawdza strukturę modelu Simulink, wyjaśnia jego architekturę i wskazuje przyczyny błędów kompilacji lub problemów przed edycją. - 100simscape-write-ssc
Pisze i poprawia pliki Simscape Language (.ssc) z komponentami, domenami i równaniami fizycznymi. - 100specifying-mbd-algorithms
Pisze specyfikacje algorytmów w Simulinku, Stateflow i MATLAB: plany systemu, architektury, implementacji i testów. - 100testing-simulink-models
Tworzy testy pass/fail w Gherkin dla modeli Simulink i podsystemów, przydatne przy regresji i sprawdzaniu poprawek. - 100simulink-configure-real-time-model
Ustawia model Simulinka pod Simulink Real-Time: wybiera plik systemowy, poprawia ustawienia solvera stałokrokowego i sprawdza zgodność.