Skip to content
Skills Library
Data & analytics · Tool integration

tuning-incremental-sync-config

/tuning-incremental-sync-config

Change the sync configuration of an existing data warehouse schema — switch sync_type, pick a different incremental_field, set primary_key_columns, choose cdc_table_mode, or change sync_frequency. Use when the user asks "switch my orders table from full refresh to incremental", "this table is syncing too slowly / too frequently", "I need to pick a different incremental column", "set up CDC for this Postgres table", or when diagnosis of a failing sync pointed to an incremental-field or PK misconfiguration.

Repository
skills ↗
Licence
MIT
Last repository change
25.10.2026

Assessment and security

100/ 100Class: good
Format25 / 25
Frontmatter with name and description, valid name, description up to 1,024 characters, name matching the folder.
Discoverability25 / 25
Description explains when to use the skill, has a reasonable length and uses third person.
Content35 / 35
At least 150 words and at most 500 lines, headings, step lists, examples or code.
Hygiene15 / 15
No placeholders such as TODO, no Windows paths, with a licence.
Riskno signals detected in the scan
Files in this package
1
Scripts
0
HTML comments
0
URLs in SKILL.md
0
Deprecation

No signals detected. Repository changed on 25.10.2026, without references to retired models or APIs.

Licence

MIT, open: use and modify while retaining author attribution.

What it does and when to use it

Change the sync configuration of an existing data warehouse schema — switch sync_type, pick a different incremental_field, set primary_key_columns, choose cdc_table_mode, or change sync_frequency. Use when the user asks "switch my orders table from full refresh to incremental", "this table is syncing too slowly / too frequently", "I need to pick a different incremental column", "set up CDC for this Postgres table", or when diagnosis of a failing sync pointed to an incremental-field or PK misconfiguration.

Triggers from the description

switch my orders table from full refresh to incrementalthis table is syncing too slowly / too frequentlyI need to pick a different incremental columnset up CDC for this Postgres table
Original author description

Change the sync configuration of an existing data warehouse schema — switch sync_type, pick a different incremental_field, set primary_key_columns, choose cdc_table_mode, or change sync_frequency. Use when the user asks "switch my orders table from full refresh to incremental", "this table is syncing too slowly / too frequently", "I need to pick a different incremental column", "set up CDC for this Postgres table", or when diagnosis of a failing sync pointed to an incremental-field or PK misconfiguration.

How it works

  1. When to use this skill
  2. Available tools
  3. The fields you can tune
  4. Workflow
  5. Specific common changes
  6. Important notes
Original SKILL.md headings · 252 lines, 1,734 words
SKILL.md preview
---
name: tuning-incremental-sync-config
description: >
  Change the sync configuration of an existing data warehouse schema — switch sync_type, pick a different
  incremental_field, set primary_key_columns, choose cdc_table_mode, or change sync_frequency. Use when the user
  asks "switch my orders table from full refresh to incremental", "this table is syncing too slowly / too
  frequently", "I need to pick a different incremental column", "set up CDC for this Postgres table", or when
  diagnosis of a failing sync pointed to an incremental-field or PK misconfiguration.
---

# Tuning incremental sync config

A sync's configuration lives on the `ExternalDataSchema` and can be changed any time via
`external-data-schemas-partial-update`. Most changes are non-destructive (take effect on the next sync), but a few
(switching sync_type, changing primary keys) require careful handling to avoid corrupting the synced data.

## When to use this skill

- The user wants to change how an already-connected table is synced
- A diagnosis flagged the incremental field or primary key as wrong
- The table is syncing too often / not often enough
- Switching an incremental table to CDC (or vice versa)
- The source table was changed on the other side (new columns, dropped columns) and the sync config needs to catch up

If the user is setting up a brand-new source, use `setting-up-a-data-warehouse-source` instead — configuration is
chosen at creation time there.

## Available tools

| Tool                                                   | Purpose                                                                   |
| ------------------------------------------------------ | ------------------------------------------------------------------------- |
| `external-data-schemas-retrieve`                       | Current sync_type, incremental_field, PKs, sync_frequency                 |
| `external-data-schemas-incremental-fields-create`      | Refresh candidate incremental fields from the live source                 |
| `external-data-schemas-partial-update`                 | Apply the config change                                                   |
| `external-data-schemas-reload`                         | Trigger a sync with the new config                                        |
| `external-data-schemas-resync`                         | Wipe and re-import from scratch when the change invalidates existing data |
| `external-data-schemas-delete-data`                    | Drop the synced table while keeping the schema entry                      |
| `external-data-sources-check-cdc-prerequisites-create` | Pre-flight Postgres CDC (only when switching to/from CDC)                 |
| `external-data-sources-webhook-info-retrieve`          | Current webhook state (when switching to/from sync_type=webhook)          |
| `external-data-sources-create-webhook-create`          | Register a webhook after switching a schema to sync_type=webhook          |
| `external-data-sources-update-webhook-inputs-create`   | Rotate a webhook signing secret                                           |
| `external-data-sources-delete-webhook-create`          | Unregister webhook when switching schemas off sync_type=webhook           |

## The fields you can tune

From the partial-update endpoint:

| Field                    | Values                                                                                   | Notes                                                              |
| ------------------------ | ---------------------------------------------------------------------------------------- | ------------------------------------------------------------------ |
| `sync_type`              | `full_refresh`, `incremental`, `append`, `cdc`, `webhook`                                | Source must support the target type — check via incremental-fields |
| `incremental_field`      | Column name from the source                                                              | Must appear in `incremental_fields` list for the schema            |
| `incremental_field_type` | `datetime`, `date`, `timestamp`, `integer`, `numeric`, `objectid`                        | Must match the column's real type                                  |
| `primary_key_columns`    | Array of column names                                                                    | Required for CDC. Used for upsert dedup on incremental             |
| `cdc_table_mode`         | `consolidated`, `cdc_only`, `both`                                                       | Only meaningful when sync_type=cdc                                 |
| `sync_frequency`         | `5min`, `15min`, `30min`, `1hour`, `6hour`, `12hour`, `24hour`, `7day`, `30day`, `never` | How often the table syncs. CDC: how often changes load, `7day` max |
| `sync_time_of_day`       | `HH:MM:SS`                                                                               | When sync_frequency is daily/weekly-scale                          |
| `should_sync`            | `true` / `false`                                                                         | Pause the schema without deleting it                               |

## Workflow

### Step 1 — Read the current config

Always start with `external-data-schemas-retrieve({id})`. Understanding the current state prevents mistakes like
"fixing" an incremental_field that's actually correct.

Note:

- Current `sync_type`, `incremental_field`, `incremental_field_type`, `primary_key_columns`
- Current `status` (don't tune a schema that's currently `Running` — wait or cancel first)
- `last_synced_at` (so you can tell if the next sync worked)
- `latest_error` if present (the error often tells you exactly what to change)

### Step 2 — If changing sync_type or incremental_field, refresh candidates

Call `external-data-schemas-incremental-fields-create({id})`. Even though the operation name says "create", it
re-reads the source and returns the current candidate fields — use it to confirm the field you want to set actually
exists on the source and which sync types are now available for this table.

The response:

```text
{
  "incremental_fields": [{"field": "updated_at", "type": "datetime", ...}, ...],
  "incremental_available": true,
  "append_available": true,
  "cdc_available": true,
  "full_refresh_available": true,
  "detected_primary_keys": ["id"],
  "available_columns": [...]
}
```

If your target `incremental_field` isn't in the list, tell the user — they need to either pick a different field or
change the source table to add one.

### Step 3 — Apply the change

Call `external-data-schemas-partial-update({id}, {...changed fields})`.

**Only send the fields that are actually changing.** Partial update means unspecified fields stay as they are.

Examples:

```json
// Switch from full_refresh to incremental
{
  "sync_type": "incremental",
  "incremental_field": "updated_at",
  "incremental_field_type": "datetime"
}

// Change sync frequency to hourly
{"sync_frequency": "1hour"}

// Fix wrong PK on a CDC table
{"primary_key_columns": ["tenant_id", "order_id"]}

// Pause a schema
{"should_sync": false}
```

### Step 4 — Decide whether existing data is still valid

This is the step that's easy to get wrong. Some config changes invalidate the synced data; others don't.

**Changes that DON'T invalidate existing data:**

- `sync_frequency`, `sync_time_of_day` — scheduling only
- `should_sync` — on/off
- `cdc_table_mode` in most cases — next sync will start writing to the new shape, but historical consolidated rows
  stay valid
- Switching between `incremental` and `full_refresh` with the same `incremental_field` — next sync just re-runs
  fresh
- Switching to or from `sync_type: "webhook"` — the synced data stays valid; only the ingestion path changes.
  Remember to register or unregister the webhook (see sections below) alongside the sync_type change.

**Changes that MAY invalidate existing data and need a resync:**

- Changing `incremental_field` to a different column — the high-water mark is from the old column and won't match.
  Without a resync you'll miss rows that were updated between the two fields' histories.
- Changing `primary_key_columns` — existing rows may be deduplicated incorrectly against new PK definitions.
- Switching from `full_refresh` to `append` — the existing rows don't have the version-history shape that append
  expects.
- Switching from `append` to `full_refresh` — opposite problem; you'll end up with duplicate historical versions.
- Switching to/from `cdc` — the table shape changes fundamentally.

When the change invalidates data, the clean flow is:

1. `external-data-schemas-partial-update` with the new config
2. Warn the user this is destructive
3. `external-data-schemas-resync` to wipe and re-import under the new config

Or `external-data-schemas-delete-data` → `external-data-schemas-partial-update` with `should_sync: true` →
`external-data-schemas-reload`. `delete-data` turns syncing off, so the update must turn it on again, or the
schedule stays paused after the reload.

### Step 5 — Trigger and confirm

For non-destructive changes, call `external-data-schemas-reload({id})` to pick up the new config immediately rather
than waiting for the schedule.

Wait a moment, then `external-data-schemas-retrieve({id})` to confirm `status = Running` then `Completed`. Report
`last_synced_at` and any new `latest_error`.

## Specific common changes

### Switching full_refresh → incremental

1. `incremental-fields-create` to confirm the desired field exists and `incremental_available: true`.
2. `partial-update`: `{sync_type: "incremental", incremental_field, incremental_field_type}`.
3. No data wipe needed — next sync just switches strategy. If the source is growing fast, the next incremental sync
   is the cheap one.

### Switching incremental → cdc (Postgres only)

1. Run `external-data-sources-check-cdc-prerequisites-create` on the parent source. Only proceed if `valid: true`.
2. `incremental-fields-create` to confirm `cdc_available: true` and see `detected_primary_keys`.
3. `partial-update`: `{sync_type: "cdc", primary_key_columns: [...], cdc_table_mode: "consolidated"}`.
4. **Resync required** — CDC tables have a different shape. Trigger `external-data-schemas-resync` after the update.
   Warn the user this wipes existing data.

### Fixing a stale incremental field after schema drift

Source dropped the `updated_at` column. Sync has been failing with "column does not exist".

1. `incremental-fields-create` to see what fields remain.
2. Pick a replacement (or switch to `full_refresh` if none are suitable).
3. `partial-update` with the new field + type (or new sync_type).
4. `reload` to retry.

### Changing primary keys on a CDC table

1. `partial-update`: `{primary_key_columns: [...]}`.
2. **Resync required** — existing CDC tombstones and upsert keys won't match the new PK definition, leading to row
   duplication or missed updates.
3. `resync`, warn the user.

### Changing sync_frequency

1. `partial-update`: `{sync_frequency: "1hour"}`.
2. No reload needed — the next scheduled sync picks up the new cadence. Or reload manually if the user wants to
   confirm nothing broke.

### Switching a schema to `sync_type: "webhook"`

Only works for sources that implement `WebhookSource` (today: Stripe) and tables where `supports_webhooks: true`
from `incremental-fields-create`.

1. `incremental-fields-create` to confirm `supports_webhooks: true` for the table.
2. `partial-update`: `{sync_type: "webhook"}`.
3. If the source doesn't already have a webhook registered (check with `webhook-info-retrieve`), call
   `external-data-sources-create-webhook-create({source_id})` to register it.
4. No resync required — the schema's existing bulk-synced data stays, and the webhook becomes the primary ingestion
   path once the next reconciliation finishes.
5. Keep `sync_frequency` set (e.g. `24hour`) — it acts as a safety-net reconciliation in case any webhook delivery
   is missed.

### Switching off `sync_type: "webhook"`

1. `partial-update`: `{sync_type: "incremental"}` (or whatever bulk type is appropriate) with the required
   `incremental_field` + `incremental_field_type`.
2. If **no other schemas** on the source are still using `sync_type: "webhook"`, call
   `external-data-sources-delete-webhook-create({source_id})` to unregister. Leaving an orphaned webhook
   registered on the source side just means events will be received and dropped — not harmful, but messy.
3. If other schemas on the source are still on webhook, leave the webhook registered — it's shared across all
   webhook-type schemas on the source.

### Rotating a webhook signing secret

The source's signing secret (e.g. Stripe's `whsec_...`) was rotated, and payloads are now failing signature
verification.

1. Grab the new secret from the source's dashboard.
2. `external-data-sources-update-webhook-inputs-create({source_id}, {inputs: {signing_secret: "whsec_..."}})`.
3. No reload needed — the next inbound webhook payload will verify against the new secret.

### Pausing a schema

1. `partial-update`: `{should_sync: false}`. Schema stops syncing but stays configured.
2. To resume later: `partial-update`: `{should_sync: true}`, then `reload` for an immediate run.

## Important notes

- **Read before you write.** Always retrieve the current config first. `partial-update` doesn't complain if you set a
  field to the value it already had, but you might be about to change something you didn't realize was already set.
- **Not every sync_type is available on every schema.** The `incremental-fields-create` response tells you what's
  available _right now_, which can be different from what was available at creation (e.g. CDC may have been
  enabled for the team since).
- **Wipe when the shape changes.** Switching sync strategy often changes the physical table. If you don't resync,
  you'll be mixing row shapes and queries will return garbage.
- **CDC needs prerequisites.** Never switch to `sync_type: "cdc"` without running `check-cdc-prerequisites-create`
  first. The sync will just fail immediately.
- **Don't touch a Running schema.** If the schema is currently running, either wait for it to finish or
  `external-data-schemas-cancel` before applying the change. Updating config mid-sync can leave the incremental
  high-water mark inconsistent.
- **Sync frequency is cheap to change.** Encourage experimentation there. Sync_type and incremental_field are
  expensive to change — encourage care.
- **Webhooks are registered at the source level, not the schema level.** Multiple webhook-type schemas on the same
  source share one webhook registration. Only delete the webhook when the _last_ webhook-type schema on that
  source is being switched away, otherwise other schemas stop receiving pushes.

Versions

RepositoryScoreLicence
This page · PostHog/skills100MIT
posthog/posthog95MIT

Identical content appears in 1 other GitHub folders. We show one copy with the highest score.

Database snapshot: 13.11.2026 · package version aa4edd9f25c7 (SHA-256 digest of the entire package)

Downloads in the last 30 days: 1 · ranking

Report a problem with this skill: harmful content, incorrect descriptions or an author’s removal request.

Similar skills

  • 100diagnosing-failed-warehouse-syncs
    Diagnose why a data warehouse sync is failing and recommend the right recovery action. Use when the user asks "why isn't my Stripe/Postgres/Hubspot sync working?", "this table has been stuck for hours", "the data in the warehouse looks wrong", or wants to troubleshoot a specific…
  • 100hubspot-warehouse-sync
    Sync HubSpot CRM data to a data warehouse (BigQuery, Snowflake, or Postgres) for analytics and reporting. Covers initial backfill of millions of records under the 500K/day rate limit, incremental CDC polling via hs_lastmodifieddate, schema-drift detection with ALTER TABLE…
  • 95diagnosing-failed-warehouse-syncs
    Diagnose why a data warehouse sync is failing and recommend the right recovery action. Use when the user asks "why isn't my Stripe/Postgres/Hubspot sync working?", "this table has been stuck for hours", "the data in the warehouse looks wrong", or wants to troubleshoot a specific…
  • 100incremental-load-setup
    Configure incremental load setup operations. Auto-activating skill for Data Pipelines. Triggers on: incremental load setup, incremental load setup Part of the Data Pipelines skill category. Use when working with incremental load setup functionality. Trigger with phrases like…
  • 90cdc-and-incremental-loading
    Guides agents through change data capture and incremental load design. Use when building or modifying watermark-based loads, upserts, deduplication, merge logic, late data handling, or replayable incremental pipelines.
  • 95setting-up-a-data-warehouse-source
    Guide the user through connecting a new data warehouse source, including databases, SaaS tools, and bucket files. Use when the user wants to "connect Stripe", "import data from Postgres", "import files from a bucket", "upload a file", "add a new data source", or pick sync…

Feedback and reports

Your message goes to Bartosz Sokoliński. An email address is needed only for a reply. See the privacy policy.