Orient a natural gas plant. Which units a feed analysis and a product specification imply, in what order, and which member skill (tech-gas-*) holds the detail for each. Use when a gas treating, liquids recovery or liquefaction line-up has to be understood or discussed.

Repository
core ↗
Licence
AGPL-3.0
Last repository change
13.11.2026

Assessment and security

100/ 100Class: good
Format25 / 25
Frontmatter with name and description, valid name, description up to 1,024 characters, name matching the folder.
Discoverability25 / 25
Description explains when to use the skill, has a reasonable length and uses third person.
Content35 / 35
At least 150 words and at most 500 lines, headings, step lists, examples or code.
Hygiene15 / 15
No placeholders such as TODO, no Windows paths, with a licence.
Riskno signals detected in the scan
Files in this package
1
Scripts
0
HTML comments
0
URLs in SKILL.md
0
Deprecation

No signals detected. Repository changed on 13.11.2026, without references to retired models or APIs.

Licence

AGPL-3.0, copyleft: przeróbki udostępniane innym muszą mieć tę samą licencję.

What it does and when to use it

Orient a natural gas plant. Which units a feed analysis and a product specification imply, in what order, and which member skill (tech-gas-*) holds the detail for each. Use when a gas treating, liquids recovery or liquefaction line-up has to be understood or discussed.

Original author description

Orient a natural gas plant. Which units a feed analysis and a product specification imply, in what order, and which member skill (tech-gas-*) holds the detail for each. Use when a gas treating, liquids recovery or liquefaction line-up has to be understood or discussed.

How it works

  1. Purpose and when to use
  2. Required inputs and missing inputs
  3. Workflow and tools
  4. Validation and failure handling
  5. Outputs and provenance
  6. Required human judgment
  7. References
Original SKILL.md headings · 99 lines, 788 words
SKILL.md preview
---
name: tech-gas-processing
description: Orient a natural gas plant. Which units a feed analysis and a product specification imply, in what order, and which member skill (tech-gas-*) holds the detail for each. Use when a gas treating, liquids recovery or liquefaction line-up has to be understood or discussed.
---

# Gas processing (hub)

## Purpose and when to use

A gas plant is a spine of units chosen by two things, the feed composition and the product
specification (Mokhatab, Poe and Mak, *Handbook of Natural Gas Transmission and Processing*,
3rd ed., Elsevier 2015, Ch 3). Use this hub to settle those two before discussing any unit, then
go to the member skill. It is a reference for the process family, not a design procedure.

## Required inputs and missing inputs

- The feed analysis: liquids content, H2S, CO2, water, inerts (N2), mercury, heavy aromatics.
- The product: sales gas, LNG or NGL, with its specification (H2S, CO2, water content,
  hydrocarbon dew point, inerts, heating value).
- Whether the acid gas can be reinjected, and whether ethane or only propane and heavier is to be
  recovered.

If the mercury analysis is missing, ask for it before calling a mercury bed missing or surplus.

## Workflow and tools

Engineering guidance only; core has no calculation for this. To record the chosen line-up as
blocks and steps of the flowsheet, use skill `process-design`.

1. Start from the product. Sales gas, LNG and NGL are three different plants, and a small change
   in one specification can change the whole line-up.
2. Pick the archetype. Dew-point control suits a lean feed; liquids recovery is chosen when the
   ethane and heavier fractions are worth extracting, which is a commercial decision before it is
   a technical one.
3. Take the usual order of the spine, and drop or add units from the feed:

```
slug catcher -> inlet separation -> acid gas removal -> dehydration -> mercury removal
  -> dew point control or NGL recovery -> nitrogen rejection -> compression -> sales gas
```

   Liquids go to stabilisation and fractionation; acid gas goes to sulfur recovery and tail-gas
   treating, or to reinjection.

What decides which units appear:

- Liquid in the feed brings condensate stabilisation.
- Acid gas brings acid gas removal and, unless it is reinjected, sulfur recovery behind it.
- High inerts bring nitrogen rejection, placed after liquids recovery because heavy aromatics
  would freeze in it.
- The depth of CO2 and water removal is set by the coldest downstream step rather than by the
  sales specification: CO2 has to go lower ahead of ethane recovery than ahead of propane
  recovery, and glycol drying suffices only for warm duty where molecular sieve is needed before
  cryogenic temperatures.
- Where the feed carries mercury, a bed belongs ahead of brazed aluminium exchangers, because
  mercury attacks aluminium. A feed shown to be free of it may need none.
- Letting the feed down for separation means recompression on the way out.

Side systems hang off the spine: sour water stripping, glycol or methanol regeneration, sulfur
degassing and storage, condensate storage and vapour recovery, flare and utilities.

| Skill | For |
|---|---|
| `tech-gas-inlet-and-separation` | Slug catchers, inlet separation, condensate stabilisation |
| `tech-gas-acid-gas-removal` | Amine and physical solvent loops, membranes, scavengers |
| `tech-gas-dehydration` | Glycol contactors and molecular sieve driers |
| `tech-gas-ngl-recovery` | Joule-Thomson, refrigeration and turboexpander recovery, fractionation |
| `tech-gas-sulfur-recovery` | Claus plants, tail-gas treating, degassing, liquid redox |
| `tech-gas-nitrogen-and-mercury` | Nitrogen rejection and mercury removal |
| `tech-gas-lng-liquefaction` | Refrigeration cycles for liquefaction, end flash |

Unit-operation fundamentals (absorbers, columns, separators) are covered by `separation-method-selection`
and `thermodynamic-model-selection` where their calculations apply.

## Validation and failure handling

- Sizing is not one case. The front end and the refrigeration are set by the rich feed case; the
  demethaniser and residue compressor by the lean or high-inert case (Mokhatab, Poe and Mak, Ch 3).
  A plant sized on one case is wrong at the other: ask which cases the basis covers.
- The literature describes line-ups confidently but control schemes and trips thinly. Treat a
  unit's control philosophy and trip matrix as project information unless a cited source states
  it.

## Outputs and provenance

A short written line-up (units in order, why each is present or absent, the feed and product
basis, open questions) for `DESIGN.md`. Say which statements are general method and which are
indicative figures from the cited chapters.

## Required human judgment

Product slate, the choice between dew-point control and deep recovery, whether acid gas is
reinjected, flexibility to later ethane rejection or recovery, and every control and safeguarding
decision are the project's.

## References

- Mokhatab, Poe and Mak, *Handbook of Natural Gas Transmission and Processing*, 3rd ed.,
  Elsevier 2015, Ch 3. Retained as general method: product-first selection, the order of the
  spine, the dependence of removal depth on the cold section. Needs review before operational
  use: the sizing-case remark and the flexibility advice, which are guidance rather than rules.
- Member skills `tech-gas-*`; `process-design`.

Versions

The database has no other skills named tech-gas-processing.

Database snapshot: 13.11.2026 · package version 2c1efd3e6a2c (SHA-256 digest of the entire package)

Downloads in the last 30 days: 0 · ranking

Report a problem with this skill: harmful content, incorrect descriptions or an author’s removal request.

Similar skills

  • 90tech-gas-lng-liquefaction
    Reference for natural gas liquefaction. Pretreatment for freeze-out, heavies removal, mixed refrigerant, cascade and expander cycles, the main cryogenic exchanger and end flash handling. Use when an LNG train or its pretreatment is being discussed or reviewed.
  • 90tech-gas-acid-gas-removal
    Reference for acid gas removal in a gas plant. The amine absorber and regenerator loop, physical and hybrid solvents, membranes and scavengers, what selects between them, and the usual failure modes. Use when H2S or CO2 removal from natural gas is being discussed or reviewed.

Feedback and reports