Use when makers need calibration workflows for sensors such as CO2 sensors, load cells, magnetometers, color sensors, or analog sensors, including warm-up behavior, reference measurements, coefficient storage, and drift checks.

Licence
MIT
Last repository change
15.10.2026

Assessment and security

90/ 100Class: good
Format25 / 25
Frontmatter with name and description, valid name, description up to 1,024 characters, name matching the folder.
Discoverability25 / 25
Description explains when to use the skill, has a reasonable length and uses third person.
Content25 / 35
At least 150 words and at most 500 lines, headings, step lists, examples or code.
Hygiene15 / 15
No placeholders such as TODO, no Windows paths, with a licence.
Riskno signals detected in the scan
Files in this package
4
Scripts
0
HTML comments
0
URLs in SKILL.md
0
Deprecation

No signals detected. Repository changed on 15.10.2026, without references to retired models or APIs.

Licence

MIT, open: use and modify while retaining author attribution.

What it does and when to use it

Use when makers need calibration workflows for sensors such as CO2 sensors, load cells, magnetometers, color sensors, or analog sensors, including warm-up behavior, reference measurements, coefficient storage, and drift checks.

Original author description

Use when makers need calibration workflows for sensors such as CO2 sensors, load cells, magnetometers, color sensors, or analog sensors, including warm-up behavior, reference measurements, coefficient storage, and drift checks.

How it works

  1. Resources
  2. When to Use
  3. Workflow
  4. Core Rules
  5. Verification
  6. Integration
  7. Shared Output Contract
Original SKILL.md headings · 76 lines, 390 words
SKILL.md preview
---
name: sensor-calibration-workbench
description: Use when makers need calibration workflows for sensors such as CO2 sensors, load cells, magnetometers, color sensors, or analog sensors, including warm-up behavior, reference measurements, coefficient storage, and drift checks.
metadata: {triggers: "sensor calibration, reference measurement, drift, coefficient"}
---

# Sensor Calibration Workbench

Use this skill when the sensor technically works, but the readings are not yet
trustworthy enough for the project.

## Resources

- `references/calibration-flow.md` - end-to-end calibration workflow and evidence checklist
- `references/common-failure-patterns.md` - warm-up, scaling, drift, saturation, and environment mistakes
- `references/persistence-and-revalidation.md` - storing coefficients and deciding when recalibration is needed

## When to Use

Use this skill when the request involves:

- volatile or implausible sensor readings
- "how do I calibrate this sensor?"
- load-cell factor tuning
- CO2, magnetometer, or color-sensor calibration
- storing calibration coefficients in EEPROM or flash
- deciding whether the problem is calibration, hardware, or environment

Do not use this skill when the sensor is not detected at all. That should route
through hardware or bus bring-up first.

## Workflow

1. Confirm the measurement problem:
   - unstable -> open `references/common-failure-patterns.md`
   - offset or scaling error -> open `references/calibration-flow.md`
   - values good once but bad later -> open
     `references/persistence-and-revalidation.md`
2. Identify the calibration class:
   - one-point or zero-offset
   - two-point scale calibration
   - multi-orientation or environmental calibration
3. Collect reference evidence before changing coefficients:
   - known reference values
   - warm-up state
   - ambient conditions
   - sample stability
4. Decide how calibration values will persist and how revalidation will be
   triggered after reboot, firmware update, or field drift.

## Core Rules

- Calibration without a known reference is guesswork.
- Warm-up and stabilization time are part of calibration, not a side note.
- Do not mix hardware-fault symptoms with coefficient-tuning symptoms.
- Store both the calibration values and enough metadata to know when they became
  stale.

## Verification

- Confirm readings converge toward a known reference after calibration.
- Confirm the calibrated values stay stable across repeated samples.
- Confirm stored coefficients reload correctly after restart.
- If the project has operating thresholds, verify those thresholds against the
  calibrated output rather than the raw sensor value.

## Integration

- Pair with `i2c-bringup-diagnostician` or `circuit-debugger` when the sensor is
  not yet electrically trustworthy.
- Pair with `arduino-code-generator` when the user needs persistence or
  filtering code added to the sketch.
- Pair with `field-power-and-connectivity-triager` when sensor behavior changes
  only off USB or under field power conditions.

## Shared Output Contract

Use [the shared Arduino skill contract](../../docs/arduino-skill-contract.md):
state assumptions, required tools and versions, implementation steps,
tests/evidence by proof stage, known limitations, and recovery/security notes.
Files in this package (4)
  • SKILL.md 3 KB
  • references/calibration-flow.md 1 KB
  • references/common-failure-patterns.md 1 KB
  • references/persistence-and-revalidation.md 1 KB

Versions

The database has no other skills named sensor-calibration-workbench.

Identical content appears in 1 other GitHub folders. We show one copy with the highest score.

Database snapshot: 13.11.2026 · package version b9cf62283cc7 (SHA-256 digest of the entire package)

Downloads in the last 30 days: 0 · ranking

Report a problem with this skill: harmful content, incorrect descriptions or an author’s removal request.

Similar skills

  • 90esp32-sensor-calibration-record
    Use when designing, reviewing, debugging or validating sensor calibration record for ESP32 firmware; apply target-specific constraints, failure analysis and measurable verification before release.
  • 90esp32-load-cells-hx711
    Use when reading load cells with HX711, diagnosing unstable weight, drift, saturation or calibration errors.
  • 100sensor-health
    Generate comprehensive sensor health and status reports across all LimaCharlie organizations. Use when users ask about sensor connectivity, data availability, offline sensors, sensors not reporting events, or fleet-wide health queries (e.g., "show me sensors online but not…
  • 100sensors
    Working with LimaCharlie sensors — listing, filtering, info, tags, installation keys, and sensor selectors. Covers both EDR agents and adapter sensors at the inventory level. Use when managing sensor inventory, checking sensor status, working with tags, creating installation…
  • 100airflow-sensors-to-orchestra
    Use this skill when an Airflow DAG contains sensor operators: S3KeySensor, FileSensor, SqlSensor, ExternalTaskSensor, TimeSensor, or any *Sensor class. Triggers: any DAG with poke_interval, mode='reschedule', or sensor-based waiting patterns. Sensors in Orchestra are first-class…
  • 100yaml-config
    Use when creating or editing Home Assistant configuration that only exists as YAML files — template sensors beyond the helper UI, REST and command-line sensors, packages, and themes — through HA NOVA Relay's opt-in file access.

Feedback and reports

Your message goes to Bartosz Sokoliński. An email address is needed only for a reply. See the privacy policy.