Skip to content
Skills Library
Programming · Testing

neqsim-input-validation

/neqsim-input-validation

Input validation rules for NeqSim simulations. USE WHEN: setting up thermodynamic systems, process equipment, or running simulations. Catches physically impossible or suspect inputs before simulation runs, saving time and providing corrective guidance.

Repository
neqsim ↗
Licence
Apache-2.0
Last repository change
27.10.2026

Assessment and security

100/ 100Class: good
Format25 / 25
Frontmatter with name and description, valid name, description up to 1,024 characters, name matching the folder.
Discoverability25 / 25
Description explains when to use the skill, has a reasonable length and uses third person.
Content35 / 35
At least 150 words and at most 500 lines, headings, step lists, examples or code.
Hygiene15 / 15
No placeholders such as TODO, no Windows paths, with a licence.
Riskno signals detected in the scan
Files in this package
1
Scripts
0
HTML comments
0
URLs in SKILL.md
0
Deprecation

No signals detected. Repository changed on 27.10.2026, without references to retired models or APIs.

Licence

Apache-2.0, otwarta: można używać i zmieniać, z zachowaniem licencji i informacji o zmianach.

What it does and when to use it

Input validation rules for NeqSim simulations. USE WHEN: setting up thermodynamic systems, process equipment, or running simulations. Catches physically impossible or suspect inputs before simulation runs, saving time and providing corrective guidance.

Original author description

Input validation rules for NeqSim simulations. USE WHEN: setting up thermodynamic systems, process equipment, or running simulations. Catches physically impossible or suspect inputs before simulation runs, saving time and providing corrective guidance.

How it works

  1. Thermodynamic System Inputs
  2. Process Equipment Inputs
  3. EOS Selection Validation
  4. Order-of-Operations Validation
  5. Quick Validation Checklist
Original SKILL.md headings · 165 lines, 1,053 words
SKILL.md preview
---
name: neqsim-input-validation
description: "Input validation rules for NeqSim simulations. USE WHEN: setting up thermodynamic systems, process equipment, or running simulations. Catches physically impossible or suspect inputs before simulation runs, saving time and providing corrective guidance."
last_verified: "2026-07-04"
---

# NeqSim Input Validation Rules

Validate inputs **before** creating NeqSim objects or running simulations.
Each rule includes the check, the error it prevents, and the corrective action.

## Thermodynamic System Inputs

### Temperature

| Check | Valid Range | Error If Violated |
|-------|------------|-------------------|
| T > 0 K (> -273.15 C) | 50-1000 K typical | Absolute zero violation — physically impossible |
| T < 2000 K | Engineering range | Above 2000 K, EOS models are not validated |
| Constructor uses Kelvin | `SystemSrkEos(273.15 + T_C, P)` | Passing Celsius directly gives wrong results silently |

**Corrective action:** Convert Celsius to Kelvin: `T_K = 273.15 + T_C`

### Pressure

| Check | Valid Range | Error If Violated |
|-------|------------|-------------------|
| P > 0 bara | 0.001-2000 bara typical | Zero/negative pressure is physically impossible |
| P < 5000 bara | Engineering range | Above ~2000 bara, cubic EOS accuracy degrades significantly |

**Corrective action:** Verify units — NeqSim uses bara (absolute), not barg (gauge) or psia.

### Composition

| Check | Rule | Error If Violated |
|-------|------|-------------------|
| Sum of mole fractions | Should be ~1.0 (tolerance: 0.999-1.001) | Wrong mixture composition — all properties incorrect |
| Each fraction >= 0 | No negative fractions | Physically impossible |
| Each fraction <= 1 | No fraction > 100% | Physically impossible |
| At least 1 component | Cannot have empty system | NeqSim crashes on empty system |

**Corrective action:** Normalize fractions: `x_i = x_i / sum(x)`. Or alert user that fractions don't sum to 1.

### Component Names

Valid component names must match entries in `src/main/resources/data/COMP.csv`.
Common correct names:

| Correct Name | Common Mistakes |
|-------------|-----------------|
| `"methane"` | `"CH4"`, `"Methane"`, `"c1"` |
| `"ethane"` | `"C2H6"`, `"C2"` |
| `"propane"` | `"C3H8"`, `"C3"` |
| `"n-butane"` | `"butane"`, `"nC4"` |
| `"i-butane"` | `"isobutane"`, `"iC4"` |
| `"CO2"` | `"co2"`, `"carbon dioxide"` |
| `"H2S"` | `"h2s"`, `"hydrogen sulfide"` |
| `"nitrogen"` | `"N2"`, `"Nitrogen"` |
| `"water"` | `"H2O"`, `"Water"` |
| `"MEG"` | `"meg"`, `"ethylene glycol"` |

**Corrective action:** Search COMP.csv for the correct component name.

### Mixing Rule

| Check | Rule | Error If Violated |
|-------|------|-------------------|
| Mixing rule is set | `setMixingRule()` must be called after `addComponent()` | Flash gives wrong results or crashes |
| CPA systems use numeric rule | `setMixingRule(10)` for CPA EOS | String mixing rules don't work with CPA |
| Classic rule for cubic EOS | `setMixingRule("classic")` for SRK/PR | Wrong rule type causes errors |

**Corrective action:** Always call `fluid.setMixingRule("classic")` (or `10` for CPA) after adding all components.

## Process Equipment Inputs

### Stream

| Check | Rule |
|-------|------|
| Flow rate > 0 | Zero flow breaks downstream equipment |
| Flow rate units specified | `setFlowRate(value, "kg/hr")` — always include unit string |
| Stream has a fluid object | `new Stream("name", fluid)` — fluid must not be null |

### Compressor

| Check | Rule |
|-------|------|
| Outlet pressure > inlet pressure | Compressor cannot decompress (use valve/expander) |
| Pressure ratio < 6 per stage | Single-stage ratio above ~4-6 is unrealistic |
| Isentropic efficiency 0.5-0.95 | Values outside this range are non-physical |
| Inlet stream has gas phase | Compressor cannot handle pure liquid |

### Valve / Throttle

| Check | Rule |
|-------|------|
| Outlet pressure < inlet pressure | Valve reduces pressure (use compressor to increase) |
| Outlet pressure > 0 bara | Cannot throttle to zero pressure |

### Heat Exchanger / Cooler / Heater

| Check | Rule |
|-------|------|
| Outlet temperature set | Must specify target temperature or duty |
| Cooler: T_out < T_in | Cooler reduces temperature |
| Heater: T_out > T_in | Heater increases temperature |
| Temperature in Kelvin for `setOutTemperature()` | Common mistake: passing Celsius to method expecting Kelvin |

### Separator

| Check | Rule |
|-------|------|
| Inlet has 2+ phases at conditions | Single-phase feed produces no separation |
| Use ThreePhaseSeparator for water | Standard Separator handles gas/liquid only |

### Pipeline

| Check | Rule |
|-------|------|
| Length > 0 meters | Zero-length pipe has no effect |
| Diameter > 0 meters | Must specify pipe inner diameter |
| Diameter typically 0.05-1.5 m | Values outside range are suspect |

## EOS Selection Validation

| Fluid Type | Required EOS | Wrong EOS Symptom |
|-----------|-------------|-------------------|
| Hydrocarbons + water | CPA (`SystemSrkCPAstatoil`) | SRK/PR gives near-zero water solubility in HC |
| Hydrocarbons + MEG/methanol | CPA (`SystemSrkCPAstatoil`) | Wrong hydrate inhibition prediction |
| Pure hydrocarbons (no polar) | SRK or PR | CPA is slower with no benefit |
| Custody transfer / fiscal metering | GERG-2008 (`SystemGERG2008Eos`) | Cubic EOS not accurate enough for custody |
| Electrolyte / brine / pH | Electrolyte CPA | SRK/CPA ignores ionic interactions |

**Corrective action:** Match EOS to fluid type. When in doubt, CPA handles the widest range of systems.

## Order-of-Operations Validation

These operations must happen in the correct sequence:

```
1. Create fluid (SystemSrkEos, etc.)
2. Add ALL components
3. Set mixing rule                    ← BEFORE characterization or flash
4. Characterize plus fractions (if oil) ← AFTER mixing rule
5. Create database (if needed)
6. Run flash (TPflash, etc.)
7. Call initProperties()              ← AFTER flash, BEFORE reading properties
8. Read properties (density, viscosity, etc.)
```

**Common order violations:**
- Characterizing before setting mixing rule → `ArrayIndexOutOfBoundsException`
- Reading properties before `initProperties()` → zero values for transport properties
- Adding components after setting mixing rule → mixing rule parameters stale

## Quick Validation Checklist

Use this checklist before every simulation setup:

- [ ] Temperature in Kelvin for constructors (not Celsius)
- [ ] Pressure in bara (not barg or psia)
- [ ] Mole fractions sum to ~1.0
- [ ] Component names match COMP.csv exactly
- [ ] Mixing rule set after all components added
- [ ] EOS matches fluid type (CPA for water/polar systems)
- [ ] Flash called before reading properties
- [ ] `initProperties()` called after flash
- [ ] Equipment connected via outlet streams (not new streams)
- [ ] ProcessSystem.run() called once after building full flowsheet

Versions

The database has no other skills named neqsim-input-validation.

Database snapshot: 13.11.2026 · package version 29cb185dc434 (SHA-256 digest of the entire package)

Downloads in the last 30 days: 0 · ranking

Report a problem with this skill: harmful content, incorrect descriptions or an author’s removal request.

Similar skills

  • 100neqsim-thermodynamic-initialization
    Select and audit NeqSim thermodynamic initialization levels for correctness and performance. USE WHEN: implementing or reviewing flashes, phase stability, EOS root selection, process-equipment thermodynamics, property access, or performance changes involving init(...) or initProperties().
  • 100neqsim-java8-rules
    Java 8 compatibility rules for NeqSim. USE WHEN: writing or reviewing any Java code for NeqSim, including tests. Covers forbidden Java 9+ features, replacement patterns, API verification, and JavaDoc requirements. All NeqSim Java code MUST compile with Java 8.
  • 90laravel-validation
    When writing validation — Form Requests, rules, custom rule objects, request-boundary design — even when the user just says 'validate this input' or 'check the request' without naming it.

Feedback and reports

Your message goes to Bartosz Sokoliński. An email address is needed only for a reply. See the privacy policy.