Devices and hardware configuration in TIA Portal Openness. Use when creating devices, finding CPUs, configuring PROFINET subnets, I/O systems, and network interfaces.

Licence
MIT
Last repository change
27.10.2026

Assessment and security

100/ 100Class: good
Format25 / 25
Frontmatter with name and description, valid name, description up to 1,024 characters, name matching the folder.
Discoverability25 / 25
Description explains when to use the skill, has a reasonable length and uses third person.
Content35 / 35
At least 150 words and at most 500 lines, headings, step lists, examples or code.
Hygiene15 / 15
No placeholders such as TODO, no Windows paths, with a licence.
Riskno signals detected in the scan
Files in this package
1
Scripts
0
HTML comments
0
URLs in SKILL.md
0
Deprecation

No signals detected. Repository changed on 27.10.2026, without references to retired models or APIs.

Licence

MIT, open: use and modify while retaining author attribution.

What it does and when to use it

Devices and hardware configuration in TIA Portal Openness. Use when creating devices, finding CPUs, configuring PROFINET subnets, I/O systems, and network interfaces.

Original author description

Devices and hardware configuration in TIA Portal Openness. Use when creating devices, finding CPUs, configuring PROFINET subnets, I/O systems, and network interfaces.

How it works

  1. Overview
  2. 🛑 MANDATORY CHECK BEFORE CODING: TypeIdentifier Requirement
  3. Required Namespaces
  4. Required Assemblies
  5. Common Patterns
  6. Quick Reference
  7. Related Files
  8. Exception Handling
Original SKILL.md headings · 326 lines, 2,341 words
SKILL.md preview
---
name: devices-and-hardware
description: Devices and hardware configuration in TIA Portal Openness. Use when creating devices, finding CPUs, configuring PROFINET subnets, I/O systems, and network interfaces.
metadata:
  siemens-depends-on: "openness-base"
---

# Devices and Hardware

## Overview

Devices represent the hardware components of a TIA Portal project, including PLCs, ET 200 stations, HMIs, and drives. Devices are created using order numbers (`CreateWithItem`), contain `DeviceItem` hierarchies, and expose hardware services such as `NetworkInterface`. PROFINET communication is configured through subnets, I/O systems, and transfer areas. Device items can be queried by classification (e.g., CPU) or by attribute info.

## 🛑 MANDATORY CHECK BEFORE CODING: TypeIdentifier Requirement

**BEFORE you write ANY code that creates devices, you MUST ask the user for the `TypeIdentifier` of every device they want to create.**

This is a **blocking requirement** — do NOT proceed to generate code without confirmed TypeIdentifiers.

### How to Ask

Use the `ask_user` tool with a clear message. Example:

```
I need the TypeIdentifier for the device you want to create.

To find the TypeIdentifier in TIA Portal:
1. Go to Options → Settings → Hardware Configuration
2. Enable "Display of the Type Identifier"
3. Browse to the device in the hardware catalog
4. Copy the TypeIdentifier (e.g., OrderNumber:6ES7 515-2UM01-0AB0/V2.9)

What TypeIdentifier should I use for [the device]?
```

### What You Must NOT Do

- ❌ Do NOT assume or guess TypeIdentifiers
- ❌ Do NOT use example TypeIdentifiers from this documentation in production code
- ❌ Do NOT skip asking just because the user mentioned a device name (e.g., "S7-1500") — the exact TypeIdentifier includes version info that is required
- ❌ Do NOT start generating code before you have all TypeIdentifiers

## Required Namespaces

```csharp
using Siemens.Engineering;
using Siemens.Engineering.HW;
using Siemens.Engineering.HW.Features;
```

## Required Assemblies

- `Siemens.Engineering.Base.dll`

**NOTE:** All device, hardware, and network types are defined in `Siemens.Engineering.Base.dll`, but **not** all in the root `Siemens.Engineering` namespace — the assembly is correct, the namespace differs per type. Confirmed mapping:
- `Siemens.Engineering` — `TiaPortal`, `Project`
- `Siemens.Engineering.HW` — `Device`, `DeviceComposition`, `DeviceItem`, `DeviceItemClassifications`, `Node`, `Subnet`, `IoSystem`, `IoController`, `IoConnector`, `NetType`
- `Siemens.Engineering.HW.Features` — `NetworkInterface`, `NetworkPort`

The DLL `Siemens.Engineering.HW.dll` does NOT exist as a separate file — `HW` and `HW.Features` are namespaces inside `Siemens.Engineering.Base.dll`. See [`openness-base`](../openness-base/SKILL.md) for the full verified namespace map and how to probe an unlisted type yourself.

## Common Patterns

### Create Device with Order Number (CreateWithItem)

**Description:** Add a device to the project using its Siemens order number and version. Devices can be created under `Project.Devices` or `Project.UngroupedDevicesGroup` for decentralized stations.

**Example:**

```csharp
var plc = project.Devices.CreateWithItem("OrderNumber:6ES7 515-2UM01-0AB0/V2.9", "", "");
var et200 = project.UngroupedDevicesGroup.Devices.CreateWithItem("OrderNumber:6ES7 155-6AU00-0CN0/V3.0", "", "");
```

**Key Types and Methods:**
- `DeviceGroup.CreateWithItem(string orderNumber, string name, string comment)` — creates a device from its order number
- `UngroupedDevicesGroup` — container for devices not nested inside another device

🛑 **Device naming — do not invent or hardcode a name when the user hasn't provided one.** The `name` parameter of `CreateWithItem` accepts an empty string `""`, and TIA Portal will then auto-generate the default station name (e.g. `"S7-1500/ET200MP station_1"`, incrementing to `_2`, `_3`, ... as needed to stay unique). If your code instead hardcodes a literal like `"PLC_1"` and that name already exists in the target project (very likely on a real/shared project, or on repeat test runs against the same project), `CreateWithItem` throws `EngineeringTargetInvocationException` with a message like `Invalid 'Name' parameter with "PLC_1" value`.

**Rule of thumb:**
- If the user explicitly specifies a device name, use it as given.
- If the user does NOT specify a name, pass `""` and let TIA Portal auto-name the device — do NOT default to a hardcoded literal such as `"PLC_1"` or `"Drive_1"`.
- Only rename after creation (e.g. via the `Name` attribute) if the user asks for a specific final name and you've confirmed uniqueness is not already handled by auto-naming.

```csharp
// User gave no name -> let TIA Portal auto-name; safe to repeat against the same project
var plc = project.Devices.CreateWithItem(plcTypeIdentifier, "", "");

// User explicitly asked for "PLC_Main" -> use it, but be aware it can still collide
var plc = project.Devices.CreateWithItem(plcTypeIdentifier, "PLC_Main", "");
```

**Note:** For a CPU like an S7-1500, `CreateWithItem` produces a full **station** device, e.g. named `"S7-1500/ET200MP station_1"` — the returned `Device` is the station, **not** the CPU. The CPU itself is a child `DeviceItem` of that station (find it via `DeviceItemClassifications.CPU`, see below). Callers that assume the returned `Device.Name` is the CPU name will look in the wrong place.

### Find CPU DeviceItem by Classification

**Description:** Locate the CPU device item within a device by filtering on its `Classification` property. Use `DeviceItemClassifications.CPU` to find processor modules.

**Example:**

```csharp
var device = Project.Devices.First(x => x.Name == "PLC_S120Democase");
var cpu = device.DeviceItems.Single(x => x.Classification == DeviceItemClassifications.CPU);
```

**Key Types and Methods:**
- `DeviceItem.Classification` — categorizes the device item type
- `DeviceItemClassifications.CPU` — constant for CPU classification

### Get NetworkInterface Service

**Description:** Obtain the `NetworkInterface` service from a device item (e.g., PROFINET interface module) to configure network settings. Check `InterfaceType` to verify the interface is Ethernet-capable.

**Example:**

```csharp
var networkInterfacePlc = cpu.DeviceItems
    .First(x => x.Name.Contains("PROFINET")).GetService<NetworkInterface>();
var nwItf = deviceItem.GetService<NetworkInterface>() is NetworkInterface nw && nw.InterfaceType == NetType.Ethernet;
```

**Key Types and Methods:**
- `NetworkInterface` — service for network interface configuration
- `NetworkInterface.InterfaceType` — type of network interface
- `NetType.Ethernet` — constant for Ethernet interfaces

### Supplementary DeviceItems Are Auto-Created by TIA Portal

**Description:** When you place the main component of a device — such as a PLC CPU, a drive Control Unit, or a distributed-I/O head module — TIA Portal automatically creates the supporting `DeviceItem`s for that component (for example network interfaces, port items, and rack items).

**Key points:**
- Do **not** try to create PROFINET interface or port `DeviceItem`s explicitly; they already exist immediately after `CreateWithItem`.
- Recurse through `device.DeviceItems` after placement to find the auto-created items you want to configure via `GetService<NetworkInterface>()`, `GetService<NetworkPort>()`, or other services.
- Only user-added extensions beyond the base unit (additional modules, optional boards, rack-inserted hardware) need explicit placement calls.

### Create and Connect to Subnet

**Description:** Create a PROFINET subnet and connect multiple device nodes to it. A node can create and auto-connect to a subnet, then other nodes can connect to the same subnet.

**Example:**

```csharp
var plcSubnet = plcNode.ConnectedSubnet;
plcSubnet ??= plcNode.CreateAndConnectToSubnet("TestSubnet");
if (et200Node.ConnectedSubnet == null)
    et200Node.ConnectToSubnet(plcSubnet);
```

**Key Types and Methods:**
- `Node.ConnectedSubnet` — the subnet this node is already connected to (nullable)
- `Node.CreateAndConnectToSubnet(string)` — creates a subnet and connects the node
- `Node.ConnectToSubnet(Subnet)` — connects a node to an existing subnet

🛑 **`ConnectToSubnet()` throws if the node is already connected** — always guard with `Node.ConnectedSubnet == null` first, exactly like `ConnectToPort` below.

🛑 **Name collisions are silent, not exceptions:** `CreateAndConnectToSubnet(name)` does **not** throw if a subnet with that name already exists elsewhere in the project — it silently returns/joins the existing one. Reusing a literal name (e.g. `"TestSubnet"`) across multiple PLC/device pairs wires new devices onto an unrelated, pre-existing subnet instead of creating a dedicated one. Derive the name from the device identity instead: `$"PROFINET_{plc.Name}"`. See [`networks-and-drivecliq`](../networks-and-drivecliq/SKILL.md) for the full write-up of this failure mode and its downstream symptoms.

### Create and Connect IoSystem

**Description:** Establish I/O control between a controller (e.g., PLC) and an I/O device (e.g., ET 200). Create an `IoSystem` on the controller side and connect the I/O device's `IoConnector`.

**Example:**

```csharp
var ioConnector = networkInterfaceEt200.IoConnectors.First();
var plcIoSystem = networkInterfacePlc.IoControllers.First().IoSystem ??
                  networkInterfacePlc.IoControllers.First().CreateIoSystem("TestIOSystem");
try
{
    ioConnector.ConnectToIoSystem(plcIoSystem);
}
catch (Exception)
{
    // ConnectToIoSystem throws if the device is already assigned to an IO system — safe to ignore
}
```

**Key Types and Methods:**
- `IoConnector` — I/O connection point on a device
- `IoController` — I/O control point on a controller
- `IoController.CreateIoSystem(string)` — creates a new I/O system
- `IoConnector.ConnectToIoSystem(IoSystem)` — connects to an existing I/O system; **throws if already connected/assigned** — wrap in try/catch or check first
- Same name-collision caveat as subnets applies to `CreateIoSystem(name)` — scope the name per PLC (e.g. `$"IO_System_{plc.Name}"`)

**Wiring order:** create the `Subnet` first, connect the controller `Node`, create the `IoSystem` on the controller side, then connect each device `IoConnector`.

### Create Multicast Transfer Area

**Description:** Create multicast-capable transfer areas between network interfaces for data exchange (e.g., DDX — Direct Data Exchange). Can be created from an existing transfer area template or explicitly configured.

**Example:**

```csharp
var newTransferArea = nwItf.MulticastableTransferAreas.Create(existingTransferArea, existingTransferArea.Type);
var newTa = nwItf.MulticastableTransferAreas.Create(partnerNwItf, TransferAreaType.DDX, "Plc2ToLead", 1);
```

**Key Types and Methods:**
- `NetworkInterface.MulticastableTransferAreas` — collection for multicast transfer areas
- `TransferAreaType.DDX` — direct data exchange transfer area type

### Port-to-Port Topology Connections

**Description:** `NetworkPort` is the physical-port service used for topology (cabling) connections. Always guard `ConnectToPort` with a `ConnectedPorts.Contains` check — the API throws if the link already exists.

**Example:**

```csharp
var port1 = deviceItem1.GetService<NetworkPort>();
var port2 = deviceItem2.GetService<NetworkPort>();

if (port1 != null && port2 != null && !port1.ConnectedPorts.Contains(port2))
    port1.ConnectToPort(port2);

// Remove an existing connection
if (port1.ConnectedPorts.Contains(port2))
    port1.DisconnectFromPort(port2);
```

**Key Types and Methods:**
- `NetworkPort` — service (`Siemens.Engineering.HW.Features`) on a port `DeviceItem`
- `NetworkPort.ConnectedPorts` — currently connected port objects
- `NetworkPort.ConnectToPort(NetworkPort)` — establishes a topology link
- `NetworkPort.DisconnectFromPort(NetworkPort)` — removes a topology link

### Find DeviceItems by Attribute Info

**Description:** Query device items by the attributes they expose. Use `GetAttributeInfos()` to inspect available attribute names and filter device items accordingly.

**Example:**

```csharp
var profinetInterfaces = cpu.DeviceItems
    .Where(d => d.GetAttributeInfos().Select(x => x.Name).Contains("PnSendClock")).ToList();
```

**Key Types and Methods:**
- `DeviceItem.GetAttributeInfos()` — returns metadata about available attributes on the device item

### Recursing Through Nested Device Groups (`DeviceUserGroup.Groups`)

**Description:** `Project.DeviceGroups` returns a collection of `DeviceUserGroup` objects. Each `DeviceUserGroup` exposes **both** a `.Devices` collection (devices directly in that group) **and** a `.Groups` collection of nested subgroups. Iterating only `.Devices` at the top level silently skips every device that sits inside a subgroup — device groups in real projects are commonly nested multiple levels deep (e.g. a project → station group → line group → individual device group), so recursion into `.Groups` is required to reach every device.

**Example:**

```csharp
static void ProcessGroup(DeviceUserGroup group, string path)
{
    foreach (Device device in group.Devices)
        ProcessDevice(device, $"{path}/{device.Name}");

    // Recurse into nested subgroups — without this, devices in subgroups are missed
    foreach (DeviceUserGroup subGroup in group.Groups)
        ProcessGroup(subGroup, $"{path}/{subGroup.Name}");
}

// Entry point: cover all three device locations in a project
foreach (Device device in project.Devices)
    ProcessDevice(device, device.Name);

foreach (DeviceUserGroup group in project.DeviceGroups)
    ProcessGroup(group, group.Name);

foreach (Device device in project.UngroupedDevicesGroup.Devices)
    ProcessDevice(device, device.Name);
```

**Key Types and Methods:**
- `Project.DeviceGroups` — top-level `DeviceUserGroup` collection
- `DeviceUserGroup.Devices` — devices directly inside this group (not recursive)
- `DeviceUserGroup.Groups` — nested subgroups; must be walked recursively to reach all devices
- To visit every device in a project, combine `project.Devices`, recursive `project.DeviceGroups`, and `project.UngroupedDevicesGroup.Devices` — devices can legitimately sit in any of the three.

### `OptionalIoDevice` Attribute on the PROFINET Interface DeviceItem

**Description:** The "optional IO device" flag seen in the TIA Portal UI (under the PROFINET interface properties of a PLC's CPU DeviceItem, or the corresponding HM/drive interface of a Startdrive device) is exposed via Openness as a plain boolean attribute named `OptionalIoDevice`. It lives on the PROFINET **interface** `DeviceItem` itself (the item representing the `X1`/`PN` port, not the parent `Device`, not the CPU/HM `DeviceItem` that owns it, and not a dedicated service). It behaves like any other read/write attribute — discoverable via `GetAttributeInfos()` and readable/writable via `GetAttribute`/`SetAttribute`, no special service (`NetworkInterface`, etc.) is required to access it.

**Example:**

```csharp
// Discover the attribute by name on a PROFINET interface DeviceItem (defensive — avoids
// hardcoding exact casing/locale differences across TIA Portal versions)
var attrInfo = interfaceItem.GetAttributeInfos()
    .FirstOrDefault(a => a.Name.IndexOf("OptionalIoDevice", StringComparison.OrdinalIgnoreCase) >= 0);

if (attrInfo != null && interfaceItem.GetAttribute(attrInfo.Name) is bool isOptional)
{
    // Read
    Console.WriteLine($"{interfaceItem.Name}: OptionalIoDevice = {isOptional}");

    // Write — e.g. clear the flag so the device becomes mandatory again
    interfaceItem.SetAttribute(attrInfo.Name, false);
}
```

**Key Types and Methods:**
- `DeviceItem.GetAttributeInfos()` / `GetAttribute(name)` / `SetAttribute(name, value)` — standard attribute access, no special service needed
- Attribute lives on the PROFINET **interface** `DeviceItem` (e.g. named `PN`, `X1`, or similar depending on device family), reached by recursing into `DeviceItems` from the CPU/HM `DeviceItem`
- As with any attribute write via Openness, the change is in-memory only until `Project.Save()` is called (or the user saves in the UI)

## Quick Reference

| Method/Pattern | Purpose |
|---|---|
| `Devices.CreateWithItem(orderNumber, name, comment)` | Create a device from order number — pass `name: ""` when the user gave no explicit name, so TIA Portal auto-generates a unique name instead of throwing on a collision |
| `DeviceItem.Classification == CPU` | Find CPU device items |
| `deviceItem.GetService<NetworkInterface>()` | Get network interface configuration |
| `Node.CreateAndConnectToSubnet(name)` | Create and join a PROFINET subnet |
| `IoController.CreateIoSystem(name)` | Create an I/O system on a controller |
| `MulticastableTransferAreas.Create()` | Create DDX transfer areas |
| `deviceItem.GetService<NetworkPort>()` | Get physical port for topology wiring |
| `port.ConnectToPort(otherPort)` | Establish port-to-port topology link (guard with `Contains` check first) |
| `DeviceItem.GetAttributeInfos()` | Inspect device item attributes |
| `DeviceUserGroup.Groups` (recursive) | Reach devices nested in subgroups — `.Devices` alone only covers the current group level |
| `interfaceItem.GetAttribute("OptionalIoDevice")` / `SetAttribute(...)` | Read/write the optional-IO-device flag on the PROFINET interface `DeviceItem` |

## Related Files

- [`online-and-download`](../online-and-download/SKILL.md) — devices are the targets for online operations and downloads
- [`security`](../security/SKILL.md) — UMAC security is configured per-device

## Exception Handling

- `EngineeringTargetInvocationException` with message like `Invalid 'Name' parameter with "PLC_1" value` is thrown when `CreateWithItem` is given a hardcoded literal name that already exists in the project. Avoid this entirely by passing `""` when the user has not specified a name (see naming rule above), instead of catching/retrying after the fact.
- `EngineeringException` is thrown if the order number is invalid or the device definition is not installed
- `InvalidOperationException` may occur when connecting nodes to incompatible subnets or I/O systems
- Null checks are required for `Node.ConnectedSubnet` and `IoController.IoSystem` as they may not exist yet
- `ConnectToPort` throws if the port link already exists — always guard with `ConnectedPorts.Contains(...)` before calling
- `ConnectToSubnet` / `ConnectToIoSystem` likewise throw if the link already exists — guard with `ConnectedSubnet == null` or wrap in try/catch
- `CreateAndConnectToSubnet(name)` / `CreateIoSystem(name)` do **not** throw on a name collision with an existing subnet/IO-system elsewhere in the project — they silently attach to it. Scope names to the device identity to avoid silently misrouting devices (see [`networks-and-drivecliq`](../networks-and-drivecliq/SKILL.md))

Versions

The database has no other skills named devices-and-hardware.

Database snapshot: 13.11.2026 · package version 8c0d82a46545 (SHA-256 digest of the entire package)

Downloads in the last 30 days: 0 · ranking

Report a problem with this skill: harmful content, incorrect descriptions or an author’s removal request.

Similar skills

  • 100openness-testing
    Live TIA Portal Openness integration-test and CI guidance. Use when building or running tests against a real TIA Portal installation, including firewall and runner setup; not for headless WPF tests.
  • 93tia-addin-scaffold
    Creating a new TIA Portal Openness project from scratch — interviews the developer about the entry model (packaged add-in or standalone Openness EXE), and, only for a packaged add-in, its entry architecture (in-process or separate EXE entry point), attach point (project tree,…
  • 100tia-multiuser
    TIA Portal Multiuser Engineering operations. Use for managing server projects, local sessions, and multiuser commissioning workflows.
  • 84tiaportal-mcp
    Drive Siemens TIA Portal (博途) end-to-end through the TiaMcpServer MCP plugin. Use whenever the user mentions TIA Portal, 博途, STEP 7, WinCC, S7-1200/1500, PLC, HMI, SCL, LAD, STL, Openness, or asks to create/modify/compile/download a project. For TIA-related tasks start with the…
  • 90tia-scaffold
    Build a TIA project FROM a validated project-spec — the create-from-spec pipeline: subnets → devices → modules → network/IP → tag tables/tags → block shells → protection setup → compile. Use when the user says "scaffold / build / create the project from this spec", "generate the…
  • 98tia-python
    Reference for Siemens TIA Scripting Python V1.4.3. Load only when the user explicitly chooses Python TIA Scripting or the TIA roadmap routes to it.

Feedback and reports

Your message goes to Bartosz Sokoliński. An email address is needed only for a reply. See the privacy policy.