Skip to content
Skills Library
Medicine & health · Building & coding

deep-learning-recon

/deep-learning-recon

Deep-learning MRI reconstruction expert. Use for training or applying neural networks to reconstruct undersampled MRI — unrolled / variational networks (VarNet, MoDL, End-to-End VarNet, deep cascade), self-supervised training without fully-sampled data (SSDU), diffusion / score-based reconstruction, and the frameworks and datasets to do it. Tools: DIRECT, fastMRI, ATOMMIC, torchkbnufft; datasets fastMRI / mridata. For classical, training-free reconstruction (ESPIRiT/SENSE/GRAPPA, L1-wavelet PICS, NUFFT gridding) hand off to the mri-reconstruction skill. Triggers: deep learning reconstruction,

Licence
MIT
Last repository change
10.10.2026

Assessment and security

100/ 100Class: good
Format25 / 25
Frontmatter with name and description, valid name, description up to 1,024 characters, name matching the folder.
Discoverability25 / 25
Description explains when to use the skill, has a reasonable length and uses third person.
Content35 / 35
At least 150 words and at most 500 lines, headings, step lists, examples or code.
Hygiene15 / 15
No placeholders such as TODO, no Windows paths, with a licence.
Riskno signals detected in the scan
Files in this package
2
Scripts
0
HTML comments
0
URLs in SKILL.md
16
Deprecation

No signals detected. Repository changed on 10.10.2026, without references to retired models or APIs.

Licence

MIT, open: use and modify while retaining author attribution.

What it does and when to use it

Deep-learning MRI reconstruction expert. Use for training or applying neural networks to reconstruct undersampled MRI — unrolled / variational networks (VarNet, MoDL, End-to-End VarNet, deep cascade), self-supervised training without fully-sampled data (SSDU), diffusion / score-based reconstruction, and the frameworks and datasets to do it. Tools: DIRECT, fastMRI, ATOMMIC, torchkbnufft; datasets fastMRI / mridata. For classical, training-free reconstruction (ESPIRiT/SENSE/GRAPPA, L1-wavelet PICS, NUFFT gridding) hand off to the mri-reconstruction skill. Triggers: deep learning reconstruction,

Original author description

Deep-learning MRI reconstruction expert. Use for training or applying neural networks to reconstruct undersampled MRI — unrolled / variational networks (VarNet, MoDL, End-to-End VarNet, deep cascade), self-supervised training without fully-sampled data (SSDU), diffusion / score-based reconstruction, and the frameworks and datasets to do it. Tools: DIRECT, fastMRI, ATOMMIC, torchkbnufft; datasets fastMRI / mridata. For classical, training-free reconstruction (ESPIRiT/SENSE/GRAPPA, L1-wavelet PICS, NUFFT gridding) hand off to the mri-reconstruction skill. Triggers: deep learning reconstruction,

How it works

  1. Papers and textbooks
  2. Evaluation and original-source credit
  3. Project research memory
  4. Tool setup before execution
  5. Method families (with citations)
  6. Frameworks & building blocks
  7. Data
  8. Training & evaluation
  9. Hand-offs
Original SKILL.md headings · 122 lines, 802 words
SKILL.md preview
---
name: deep-learning-recon
description: >-
  Deep-learning MRI reconstruction expert. Use for training or applying neural
  networks to reconstruct undersampled MRI — unrolled / variational networks
  (VarNet, MoDL, End-to-End VarNet, deep cascade), self-supervised training
  without fully-sampled data (SSDU), diffusion / score-based reconstruction, and
  the frameworks and datasets to do it. Tools: DIRECT, fastMRI, ATOMMIC,
  torchkbnufft; datasets fastMRI / mridata. For classical, training-free
  reconstruction (ESPIRiT/SENSE/GRAPPA, L1-wavelet PICS, NUFFT gridding) hand off
  to the mri-reconstruction skill. Triggers: deep learning
  reconstruction, unrolled network, variational network, MoDL, end-to-end
  VarNet, data consistency, self-supervised MRI reconstruction, diffusion model
  reconstruction, score-based, fastMRI, physics-guided network.
metadata:
  author: Ke Wang
  version: "0.8.0"
---

# MRFoundry: Deep-Learning MRI Reconstruction

You are a DL-recon researcher. **Unrolled networks** combine iterative solver
steps with learned regularizers/updates and measurement consistency. Evaluate
the forward model and data consistency, but do not treat consistency as proof
of feature fidelity: undersampling leaves information unconstrained, and priors
can influence that information even when measurement residuals are small.


## Papers and textbooks

See the [annotated reading list](references/reading-list.md) for primary papers,
textbooks, publication details, direct source links and what each source supports.
Use the [repo-wide reference index](https://github.com/KeWang0622/MRFoundry/blob/main/REFERENCES.md) to navigate across skills.
When using a method, cite its specific source; distinguish paper evidence from
software instructions and current venue/safety requirements.


## Evaluation and original-source credit

Before comparing methods or making scientific claims, identify the intended task
and the evidence needed to support it. Use the [evaluation and attribution guide](https://github.com/KeWang0622/MRFoundry/blob/main/skills/mri-research/references/evaluation-and-attribution.md)
for evaluation planning, failure tests and auditing citations in the actual output.
Report benchmark metrics when relevant; do not infer universal superiority or
clinical validity from them. Cite original methods and software separately, and
flag claims whose source or support could not be verified.
If the shared guide is absent in a standalone install, retrieve
`skills/mri-research/references/evaluation-and-attribution.md` from the
[official repository](https://github.com/KeWang0622/MRFoundry).

## Project research memory

If only the legacy `.mri-research/` notebook exists, migrate it with the project
memory initializer before creating new notes; preserve existing evidence.
For project experiments, read `.mrfoundry/INDEX.md` when present and retrieve
only relevant preferences, environment notes and evidence-linked lessons. After
meaningful runs or corrections, record outcomes, failures, limitations and next
steps; revise scoped lessons without erasing history. Keep user preferences
separate from scientific findings. Use the [project memory workflow](https://github.com/KeWang0622/MRFoundry/blob/main/skills/mri-research/references/project-memory.md)
to initialize the folder or connect project `CLAUDE.md` / `AGENTS.md`. If the hub
is absent, retrieve the reference from the official skill repository.

## Tool setup before execution

For any application this skill uses, check for a compatible installation and
follow the official upstream's setup instructions. Within the authorized task,
install missing dependencies yourself in an isolated environment, run a small
upstream example, then execute the user's workflow. Do not leave routine setup
to the user or replace a missing tool with a homemade numerical implementation.
Use established simulators/solvers; write only necessary configuration and glue.
If blocked, report the actual obstacle and an established alternative.
Read the [tool setup guide](https://github.com/KeWang0622/MRFoundry/blob/main/skills/mri-research/references/tool-setup.md) when installing,
repairing, or choosing an execution environment. If the hub is not installed,
retrieve that reference from the official `KeWang0622/MRFoundry` repository.

## Method families (with citations)

- **Variational Network (VN)** — Hammernik et al., *MRM* 2018;79(6):3055–3071.
  Code: https://github.com/VLOGroup/mri-variationalnetwork
- **MoDL** — CNN prior + CG data consistency, weight-shared. Aggarwal et al.,
  *IEEE TMI* 2019. Code: https://github.com/hkaggarwal/modl
- **End-to-End VarNet** — learns coil sensitivities too; strong fastMRI baseline
  (Sriram et al., MICCAI 2020) — in the fastMRI repo.
- **SSDU (self-supervised, no fully-sampled data)** — split acquired k-space into
  DC and loss sets. Yaman et al., *MRM* 2020. Code:
  https://github.com/byaman14/SSDU
- **Diffusion / score-based** — learned generative prior + measurement
  consistency; sampling-pattern-agnostic, inference-heavy. Chung & Ye, *MedIA*
  2022 (https://github.com/hyungjin-chung/score-MRI); Jalal et al., NeurIPS 2021
  (https://github.com/utcsilab/csgm-mri-langevin).
- **AUTOMAP** — end-to-end domain-transform learning (Zhu et al., *Nature* 2018);
  instructive but memory-heavy.

## Frameworks & building blocks

- **DIRECT** — https://github.com/NKI-AI/direct — many baselines + training loops.
- **fastMRI** — https://github.com/facebookresearch/fastMRI — reference models
  (U-Net, VarNet, E2E-VarNet), transforms, and challenge-matched evaluation.
  **Archived upstream in 2025**: still the canonical baseline, but treat it as a
  frozen reference rather than a maintained framework.
- **ATOMMIC** — https://github.com/wdika/atommic — data-consistency-focused
  toolbox spanning recon, segmentation, and quantitative tasks. It **supersedes
  `mridc`**, which the same author archived (read-only since Apr 2024) and
  redirects here; don't start new work on `mridc`.
- **torchkbnufft** — https://github.com/mmuckley/torchkbnufft — differentiable
  NUFFT to drop non-Cartesian physics into a network.

## Data

**fastMRI** (knee/brain/prostate/breast) is the benchmark; requires a signed
**data-use agreement** (https://fastmri.med.nyu.edu). Fully-open alternative for
prototyping: mridata.org.

## Training & evaluation

- Select endpoints for the intended use before training/tuning. Report benchmark
  metrics with their conventions when useful, alongside task-relevant evidence.
  Distinguish perceived image quality from measured diagnostic performance;
  adding SSIM, VIF/LPIPS or appearance ratings does not establish the latter.
- **Watch for hallucination:** generative/high-acceleration recon can synthesize
  plausible but false structure. Test stability and out-of-distribution
  robustness; prefer data-consistency-anchored architectures.

- **Name the shipping baseline.** Vendor DL reconstruction (Siemens *Deep
  Resolve*, GE *AIR Recon DL*, Philips *SmartSpeed*) is the de-facto clinical
  comparator; reviewers will ask, so address it in related work even though the
  implementations are proprietary.

## Hand-offs

- **Classical / training-free recon** — ESPIRiT, SENSE, GRAPPA, L1-wavelet PICS,
  NUFFT gridding, or "just get me an image from this k-space": use the
  `mri-reconstruction` skill, which executes BART/SigPy pipelines. You also want
  it for the *baseline* your network is compared against.
- **Sampling-pattern or trajectory design** (including learned sampling that must
  run on a scanner): `pulse-sequence-design`.
- **Theory, citations, and the wider landscape:** the `mri-research` hub.

Deeper reference:
https://github.com/KeWang0622/MRFoundry/blob/main/skills/mri-research/references/recon-methods.md
Files in this package (2)
  • SKILL.md 8 KB
  • references/reading-list.md 2 KB

Versions

The database has no other skills named deep-learning-recon.

Database snapshot: 13.11.2026 · package version 48860232b863 (SHA-256 digest of the entire package)

Downloads in the last 30 days: 0 · ranking

Report a problem with this skill: harmful content, incorrect descriptions or an author’s removal request.

Similar skills

  • 100mri-reconstruction
    Actionable MRI image reconstruction — turn raw k-space into an image, and actually run it. Use this WHENEVER the user wants to reconstruct MR data or says things like "reconstruct this k-space", "run BART on this", "get an image from this .cfl / .h5 / twix file", or asks about…
  • 95nnunet-segmentation
    Medical image segmentation with nnU-Net's self-configuring framework — auto-selects architecture, preprocessing, training for any modality. CT, MRI, microscopy, ultrasound in 2D, 3D full-res, 3D low-res, cascade. Pipeline: convert → plan/preprocess → train (5-fold CV) → best…
  • 100ml-expert
    Expert-level machine learning, deep learning, model training, and MLOps. Use when the user mentions machine learning, deep learning, neural networks, MLOps, or data science, or when the task involves Machine Learning Fundamentals, Data Preparation, or Model Training.
  • 100ct2abaqus-skills
    Convert uploaded CT/MRI volumes and anatomical segmentations into auditable Abaqus volume meshes and CAE previews. Use for DICOM, NIfTI, NRRD or Slicer image-to-model reconstruction, including segmentation preparation when only images are available.

Feedback and reports

Your message goes to Bartosz Sokoliński. An email address is needed only for a reply. See the privacy policy.